P7S-14P Omron, P7S-14P Datasheet - Page 6

SOCKET PC MNT FOR G7S RELAY

P7S-14P

Manufacturer Part Number
P7S-14P
Description
SOCKET PC MNT FOR G7S RELAY
Manufacturer
Omron
Series
G7Sr
Type
Socketr
Datasheets

Specifications of P7S-14P

Mounting Type
Through Hole
Number Of Positions
14
Termination Style
PC Pin
Current Rating
6A
Terminal Type
Through Hole
No. Of Pins
14
Svhc
No SVHC (15-Dec-2010)
Accessory Type
Socket
External Depth
47mm
External Length / Height
80.5mm
External
RoHS Compliant
Associated Relay Series
G7S
Mounting Style
Through Hole
Width
23 mm
Socket Mounting
Through Hole
Socket Terminals
Quick Connect
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
G7S Series
For Use With
Z2362 - RELAY SAFETY 6A 24VDC PLUG-INZ2363 - RELAY SAFETY 6A 24VDC PLUG-IN
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
P7S14P
Z2418

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P7S-14P
Manufacturer:
Omron Electronics Inc-EMC Div
Quantity:
135
Precautions
J FORCIBLY GUIDED CONTACTS
When NO contacts are welded, the coil will be non-energized so
all NC contacts will maintain a distance between the contacts of
0.5 mm minimum. Likewise if NC contacts are welded, the coil
will be energized so all contacts will maintain a distance between
each other of 0.5 mm minimum.
Do not touch the terminal area of the Relays or the socket ter-
minal area (charged area) while power is ON. Electric shock
will result.
OMRON ELECTRONICS LLC
One Commerce Drive
Schaumburg, IL 60173
847-843-7900
For US technical support or other inquiries:
800-556-6766
Cat. No. GC SAFETY-2A
!
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
Caution
2/03-11/06
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
416-286-6465
Specifications subject to change without notice
7
J SAFETY RELAYS
A Safety Relay is a relay with which a safety circuit can be
configured. For common precautions when using and handling
relays, consult Omron.
J CONTACTS
The coil terminals have polarity (positive and negative).Operation
is not possible if these are connected in reverse.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca