MM4KP DC24 Omron, MM4KP DC24 Datasheet - Page 5

no-image

MM4KP DC24

Manufacturer Part Number
MM4KP DC24
Description
RELAY POWER 4PDT 5A 24VDC
Manufacturer
Omron
Series
MMKr
Datasheet

Specifications of MM4KP DC24

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
113mA
Coil Voltage
24VDC
Turn On Voltage (max)
19.2 VDC
Mounting Type
Socket
Termination Style
14 Pin Socketable
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
5A @ 220VAC
Control On Voltage (max)
19.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
 Details
Other names
MM4KPDC24
MM4KPDC24NC
■ Contact Ratings
Standard Relays
DC-switching Relays
Note: 1. When switching DC inductive loads at 125 V or more, an unstable region exists for a switching current of between 0.5 and
Contacts (Conforming to Auxiliary Power Relay Specifications)
Note: 1. When switching DC inductive loads at 125 V or more, an unstable region exists for a switching current of between 0.5 and
Contact mechanism
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Contact mechanism
Contact material
Rated load
Rated current flow
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Contact mechanism
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
2. If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the
2. If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the
2.5 A. The Relay will not turn OFF in this region. Use a switching current of 0.5 A or less when switching 125 VDC or more.
circuit must be designed to ensure that an arc-breaking time of 50 ms is not exceeded.
2.5 A. The Relay will not turn OFF in this region. Use a switching current of 0.5 A or less when switching 125 VDC or more.
circuit must be designed to ensure that an arc-breaking time of 50 ms is not exceeded.
Item
Item
Item
Single
Ag
10 A at 220 VAC
7 A at 24 VDC
10 A
250 VAC, 250 VDC
10 A
2,200 VA, 168 W
Single
Ag
7 A at 110 VDC
10 A
250 VAC, 250 VDC
10 A
800 W, 20 VA
Single
Ag
5 A at 220 VAC, 4 A at 24 VDC
5 A
250 VAC, 250 VDC
5 A
Open Relays: MM2XK(B), MM3XK(B), MM4XK(B)
Open Relays: MM2K(B), MM3K(B), MM4K(B)
Resistive load
Resistive load
Resistive load
(cosφ = 1)
(cosφ = 1)
(cosφ = 1)
MM4KP-JD
6 A at 110 VDC
660 W, 20 VA
(cosφ = 0.4, L/R= 7 ms)
(cosφ=0.4, L/R=7 ms)
(cosφ=0.4, L/R=7 ms)
Inductive load
Inductive load
Inductive load
5 A at 220 VAC
4 A at 24 VDC
5 A
250 VAC, 250 VDC
5 A
1,100 VA, 96W
5 A at 110 VDC
5 A
250 VAC, 250 VDC
5 A
700 W, 20 VA
5 A at 110 VDC
Cased Relays: MM2XKP, MM3XKP, MM4XKP
Resistive load
Resistive load
Resistive load
Cased Relays: MM2KP, MM3KP, MM4KP
(cosφ = 1)
(cosφ = 1)
(cosφ = 1)
MM4XKP-JD
600 W, 20 VA
(cosφ = 0.4, L/R= 7 ms)
(cosφ=0.4, L/R=7 ms)
(cosφ=0.4, L/R=7 ms)
Inductive load
Inductive load
Inductive load
MMK
5

Related parts for MM4KP DC24