MM4KP DC24 Omron, MM4KP DC24 Datasheet
MM4KP DC24
Specifications of MM4KP DC24
MM4KPDC24NC
Related parts for MM4KP DC24
MM4KP DC24 Summary of contents
Page 1
... Japan Electromechanical Commission. Furthermore, the MM4KP-JD and MM4XKP-JD satisfy the ratings of multi-contact relays provided in JEC-174D (1979) standards for power auxiliary relays. These models work at operation level A specified by JEC-174D (1979) standards and the hot start of the relays is possible after the coils radiate heat. ...
Page 2
Open Coils (with Screw Terminals) Type Standard DC-switching Cased Coils (Plug-in Terminals) Type Standard DC-switching Conforming to auxiliary power relay specifications Conforming to auxiliary power relay specifications for DC-switching Model Number Legend MM@@ Contact Form 2: ...
Page 3
... Performance characteristic data are measured at a coil temperature of 23°C. 3. The AC coil resistance values are reference values. 4. The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously. ∗Values in parentheses are for open relays. DIN Track/Front-connecting Socket Screw terminals ...
Page 4
Reset Coil Rated voltage (V) Rated current (mA 770 690 12 385 345 24 191 170 100/(110) 46 41/46 200/(220) 23 20/ 422 12 215 24 109 48 58 ...
Page 5
... Max. switching voltage 250 VAC, 250 VDC Max. switching current 10 A Max. switching power 2,200 VA, 168 W (reference value) DC-switching Relays Item Open Relays: MM2XK(B), MM3XK(B), MM4XK(B) Resistive load (cosφ Contact mechanism Single Contact material Ag Rated load 110 VDC Rated current flow 10 A Max ...
Page 6
... Note: 1. The data shown above are initial values. 2. The electrical endurance was measured at an ambient temperature of 23°C. 3. This value was measured at a switching frequency of 60 operations per minute. Open or bifurcated-contact Relays 1,800 operations/hr 1,800 operations/hr (under rated load Hz, 0.375 mm single amplitude (0.75 mm double amplitude Hz, 0 ...
Page 7
... Engineering Data ■ Standard Relays Maximum Switching Power Open Relays MM@K(B) AC resistive load AC inductive load (cosφ = 0.4) DC resistive load DC inductive load (L ms) Switching voltage (V) Endurance Curves Open Relays MM@K(B) 10,000 5,000 220 VAC resistive load 3,000 Inductive load (cosφ = 0.4) ...
Page 8
... VDC resistive load 1,000 500 110 VDC inductive load 300 (L/R 7 ms) Switching current (A) ■ Relays Conforming to Auxiliary Power Relay Specifications Maximum Switching Power MM4KP-JD AC inductive load AC resistive load cosφ = 0.4 DC resistive load DC inductive load L Switching voltage (V) ...
Page 9
... Ambient temperature (°C) Ambient Temperature vs. Coil Temperature Rise MM4KP 110 VAC (60 Hz) Number of Relays: 5 Contact carry current Set coil Reset coil Ambient temperature (°C) MM4KP DC Number of Relays: 5 Contact carry current Set coil Reset coil Ambient temperature (°C) MMK Malfunctioning Shock MM4(X)KP 60 min. Reset 60 min ...
Page 10
... Note: All units are in millimeters unless otherwise indicated. ■ Open Relays with Solder Terminals MM2(X)K, MM3(X)K, MM2(X)K MM4(X max. 22 ±0.2 44 max. MM2K Note: Connect the common (C) of MM@XK to positive (+). ■ Open Relays with Screw Terminals MM2(X)KB, MM3(X)KB, MM2(X)KB MM4(X) Ten, M3.5 x 5.5 terminal screws 92 max. 22 ±0.2 60 max. ...
Page 11
... Cased Relays with Plug-in Terminal MM2(X)KP 54.5 max. (see note) 22 3.5 5 80.5 max. 64.5 max. Note recommended that 55 mm min. is allowed MM2KP for this side because the MM2XKP has a curved protective plate on the side. MM3(X)KP 72.5 max. MM4(X)KP (see note) 80 ...
Page 12
MM4KP-JD 72.5 max. 70.5 max. 64.5 max. MM4XKP-JD 73 max. 70.5 max. 64.5 max. Accessories ■ Sockets Relay model MM2(X)KP 11PFA MM3(X)KP 14PFA MM4(X)KP MM4(X)KP-JD 14PFA Note: When using the MM@KP-JD by itself, the PL15 Back-connecting Socket cannot be used. ...
Page 13
... Do not allow voltage to be applied simultaneously to both the set and reset coil. If voltage is applied simultaneously, the Relay will be set. • There is no reason to apply voltage to Latching Relays continu- ously because they will latch properly with a single pulse of suffi- cient width. Continuously applying voltage will only waste power. ...
Page 14
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...