G2R-1-SN AC110(S) Omron, G2R-1-SN AC110(S) Datasheet - Page 15

RELAY SPDT 110VAC PLUG-IN W/LED

G2R-1-SN AC110(S)

Manufacturer Part Number
G2R-1-SN AC110(S)
Description
RELAY SPDT 110VAC PLUG-IN W/LED
Manufacturer
Omron
Series
G2RSr
Datasheets

Specifications of G2R-1-SN AC110(S)

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
10A
Switching Voltage
440VAC, 125VDC - Max
Coil Type
Standard
Coil Current
8.2mA
Coil Voltage
110VAC
Turn On Voltage (max)
88 VAC
Turn Off Voltage (min)
33 VAC
Mounting Type
Socket
Termination Style
Quick Connect - .187" (4.7mm)
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
88 VAC
Control Off Voltage (min)
33 VAC
Contact Rating
10 A
Contact Termination
Pin
Mounting Style
Plug-In
Power Consumption
0.9 VA
Contact Material
Silver Alloy
Coil Resistance
5.566 K Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-1-SNAC110(S)
G2R1SNAC110S
■ Latching Relays
• Avoid use in locations subject to excessive magnetic particles or
• Avoid use in magnetic fields (over 8,000 A•m).
• Take measures to preventing problems caused by vibration or
Drive Circuit (Dual Coil Latching Relays G5AK, G6AK, G6BK, etc.)
When a DC-switching latching relay is used in one of the circuits shown in the following diagram, the relay contacts may be released from the locked
state unless a diode (enclosed in the dotted box in the circuit diagram) is connected to the circuit.
When connecting a diode to the relay circuit, be sure to use a diode with a repetitive peak-inverse voltage, and a DC reverse voltage sufficient to
withstand external noise or surge. Also be sure that the diode has an average rectified current greater than the coil current.
If the contact of the relay is used to de-energize the relay, the relay may not operate normally. Avoid using the relay in a circuit like the one shown
below:
dust.
shock. Problems may originate from other relay(s) operating or
releasing on the same panel.
Circuit connecting two reset coils in parallel.
Circuit connecting two set coils in parallel
(+)
(−)
(+)
(−)
S
S
K
1
S
D
D
R
S
1
1
1
R
1
K
1
S
S
2
2
S
S
D
R
S
D
R
2
3
K
2
Incorrect Use:
2
K
2
S
Electromechanical Relays
3
Circuits
X
X
• Avoid simultaneous energization of the set and reset coils, even
• Avoid use under conditions where excessive surge-generating
• When planning to mount multiple relays side-by-side, observe the
b
L
X
X
though both coils can be continuously energized.
sources exist in the coil power source.
minimum mounting interval of each type of relay.
L
b
: Latching relay
: NC contact of relay
Circuit connecting set coil of latching relay
in parallel with another relay coil.
Technical Information
Circuit connecting set coil to reset coil.
(+)
(−)
Load
(+)
(−)
S
K
1
D
S
1
R
D
1
S
1
S
S
S
2
K
S
S
2
D
2
3
2
R
R
S
S
3
4
15

Related parts for G2R-1-SN AC110(S)