CHIPPROG-40 Phyton Inc, CHIPPROG-40 Datasheet - Page 86

PROGRAMMER STANDALONE 40-DIP

CHIPPROG-40

Manufacturer Part Number
CHIPPROG-40
Description
PROGRAMMER STANDALONE 40-DIP
Manufacturer
Phyton Inc
Type
Universal, Stand Aloner
Datasheets

Specifications of CHIPPROG-40

Contents
Programmer, Cables, CD, Power Adapter
Ic Product Type
Programmer, Universal
Ic Interface Type
USB
Features
Embedded Script Language For Automation Of Routine Operations, Splits Files To Multiple Images
Rohs Compliant
Yes
For Use With/related Products
EEPROM, EPROM, FLASH, MCU, NVRAM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
5.3.4
5.3.5
5.3.6
86
How to read a device
How to verify programming
How to save data on a disc
6. Some microcontrollers can be protected against unauthorized reading of the written code by setting
7. After every operation above make sure that you watch the Ok [xxxxx... Ok] message in the
1. After you have read out the device content into the
2. In the pop-up dialog specify the destination file name, format, start and end addresses of the source
ChipProg Device Programmers
IMPORTANT! After programming of all the memory layers (Code, Data, User, etc.) you need to
program the options preset in the
been modified. Go down to the Device parameters & ID line, expand it if collapsed, select the
Program function and double click it.Device and Algorithm Parameters window
a set of Lock bits. Go down to the Lock bits line, expand it if collapsed and double click the lock
bit# lines one by one. You can optionally lock only certain parts of the device memory. Continue
until every lock bit is set.
Operation Progress box of the Program Manager tab. In case you get an error message stop the
programming and troubleshoot the issue.
There are several ways for reading the device content to an active buffer:
the Execute button or
then wait for the message Reading … OK in the
message if the device could not be read out.
There are several ways for checking if the device was programmed correctly:
or
the Execute button or
then wait after that which Verifying …
if the device failed during the verification process.
to save the read data on a PC disc. To save the data:
a) Click the Save button on the local toolbar of the Buffer window or
b) Select the Main menu > File > Save
(the buffer), and the source sub-level, and click OK.
a) Click the Read button on the main toolbar or
b) Double click on the Read function line in the Function list of the window or
c) Select the Read function line in the Function list of the
d) Select the Main menu > Commands and click on the Read line
a) Click the Verify button on the main toolbar or
b) Double click on the Verify function line in the Function list of the
c) Select the Verify function line in the Function list of the
d) Select the Main menu > Commands and click on the Verify line
Device and Algorithm Parameters Editor
OKProgram Manager
Program Manager
© 2010 Phyton, Inc. Microsystems and Development Tools
Buffer
or a specified
Program Manager
Program Manager
window or for the warning message
Program Manager
window or for the warning
Buffer layer
window, if they have
window and click
window and click
you may need
window

Related parts for CHIPPROG-40