Using the Monitor/Debug Firmware
SET
Usage:
The SET command allows the setting of user-configurable options within dBUG. With no arguments, SET
displays the options and values available. The SHOW command displays the settings in the appropriate
format. The standard set of options is listed below.
Examples:
To set the baud rate of the board to be 19200, the command is:
2-30
baud - This is the baud rate for the first serial port on the board. All communications between
dBUG and the user occur using either 9600 or 19200 bps, eight data bits, no parity, and one stop
bit, 8N1, with no flow control.
base - This is the default radix for use in converting a number from its ASCII text representation
to the internal quantity used by dBUG. The default is hexadecimal (base 16), and other choices are
binary (base 2), octal (base 8), and decimal (base 10).
client - This is the network Internet Protocol (IP) address of the board. For network
communications, the client IP is required to be set to a unique value, usually assigned by your local
network administrator.
server - This is the network IP address of the machine which contains files accessible via TFTP.
Your local network administrator will have this information and can assist in properly configuring
a TFTP server if one does not exist.
gateway - This is the network IP address of the gateway for your local subnetwork. If the client IP
address and server IP address are not on the same subnetwork, then this option must be properly
set. Your local network administrator will have this information.
netmask - This is the network address mask to determine if use of a gateway is required. This field
must be properly set. Your local network administrator will have this information.
filename - This is the default filename to be used for network download if no name is provided to
the DN command.
filetype - This is the default file type to be used for network download if no type is provided to the
DN command. Valid values are: “srecord”, “coff”, and “elf”.
mac - This is the ethernet Media Access Control (MAC) address (a.k.a hardware address) for the
evaluation board. This should be set to a unique value, and the most significant nibble should
always be even.
set
See the SHOW command for a display containing the correct formatting of
these options.
SET <option value>
baud 19200
M5249C3 User’s Manual, Rev. 1
NOTE
Set Configurations
Freescale Semiconductor