QB-78K0MINI Renesas Electronics America, QB-78K0MINI Datasheet - Page 50

no-image

QB-78K0MINI

Manufacturer Part Number
QB-78K0MINI
Description
78K0 MINICUBE SER ON CHIP DEBUG
Manufacturer
Renesas Electronics America
Datasheets

Specifications of QB-78K0MINI

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
48
T11=40 s
T11=31 s
<When Interrupts are enabled (EI) (with an RRM generated while a user program main routine is running)>
<When Interrupts are disabled (DI) (with an RRM generated while a user program interrupt service routine is running)>
D
(17) Software break
(18) Setting of “Monitor Clock”
(19) Caution on performing step execution
(20) Software break in RAM area
(21) Execution time when using pseudo real-time RAM monitor function
A
instruction for which the software break is set and that has been substituted by a debug instruction remains as is.
To avoid this, select “Object” in the Download dialog box and download the load module. In particular, take care
regarding this point when activating the debugger using a project file, as well as when using PM plus.
dialog box, the clock source of the device is changed to the clock from QB-78K0MINI during a break. If the
peripheral emulation function does not stop (by selecting "Non Break" for "Peripheral Break"), due to clock
changes, timing may differ from the timing in the actual operation. In order to adjust the clock timing even during
a break, mount an oscillator with the same frequency as the actual clock, in QB-78K0MINI.
Note Devices in which “OCD Control Code V1.xx” is displayed by selecting [About…] from the [Help] menu in the
“Run-Break” specified.
external RAM area; otherwise the break may not occur normally. Even if the break occurs, the program before
being overwritten is automatically restored.
operating frequency = 5 MHz and PCC = 0.
If the debugger does not terminate normally due to a factor such as a freeze while a software break is set, the
With a device such as the 78K0/Kx1+
Some peripheral registers remains stopped during step execution. In such a case, execute the instruction with
Do not overwrite the program in which a software break has been set to the internal low-speed RAM area or
Therefore, be sure set a software break after the program is overwritten.
The following shows the execution time when using the pseudo real-time RAM monitor function, whereas the
µ
µ
T1=106 s
ID78K0-QB.
T12=58 s
B
µ
µ
T13=8 s
A
µ
One cycle = Several tens of ms to several hundres of ms
C
T0=19 s
A
µ
C
Note
User’s Manual U17029EJ3V0UM
CHAPTER 6 CAUTIONS
T2=35 s
T2 occurs for the number of bytes loaded with RAM function
, when "System" is selected for "Monitor Clock" in the Configuration
A
µ
C
T0=19 s
A
µ
C
T2=35 s
A
µ
C
T0=19 s
A
µ
C

Related parts for QB-78K0MINI