TOOLSTICK540DC Silicon Laboratories Inc, TOOLSTICK540DC Datasheet - Page 182

DAUGHTER CARD TOOLSTICK F540

TOOLSTICK540DC

Manufacturer Part Number
TOOLSTICK540DC
Description
DAUGHTER CARD TOOLSTICK F540
Manufacturer
Silicon Laboratories Inc
Series
ToolStickr
Type
MCUr

Specifications of TOOLSTICK540DC

Contents
Daughter Card
Processor To Be Evaluated
C8051F54x
Processor Series
C8051F54x
Interface Type
USB
Operating Supply Voltage
2.7 V to 3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F54x
For Use With
336-1345 - TOOLSTICK BASE ADAPTER336-1182 - ADAPTER USB DEBUG FOR C8051FXXX
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1717
C8051F54x
LIN Register Definition 19.6. LIN0ST: LIN0 Status Register
Indirect Address = 0x09
182
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
WAKEUP
ACTIVE
ERROR
ABORT
DTREQ
LININT
DONE
Name
ACTIVE
IDLT
R
7
0
LIN Active Indicator Bit.
0: No transmission activity detected on the LIN bus.
1: Transmission activity detected on the LIN bus.
Bus Idle Timeout Bit. (slave mode only)
0: The bus has not been idle for four seconds.
1: No bus activity has been detected for four seconds, but the bus is not yet in Sleep
mode.
Aborted Transmission Bit. (slave mode only)
0: The current transmission has not been interrupted or stopped. This bit is reset to 0
after receiving a SYNCH BREAK that does not interrupt a pending transmission.
1: New SYNCH BREAK detected before the end of the last transmission or the STOP
bit (LIN0CTRL.7) has been set.
Data Request Bit. (slave mode only)
0: Data identifier has not been received.
1: Data identifier has been received.
Interrupt Request Bit.
0: An interrupt is not pending. This bit is cleared by setting RSTINT (LIN0CTRL.3)
1: There is a pending LIN0 interrupt.
Communication Error Bit.
0: No error has been detected. This bit is cleared by setting RSTERR (LIN0CTRL.2)
1: An error has been detected.
Wakeup Bit.
0: A wakeup signal is not being transmitted and has not been received.
1: A wakeup signal is being transmitted or has been received
Transmission Complete Bit.
0: A transmission is not in progress or has not been started. This bit is cleared at the
start of a transmission.
1: The current transmission is complete.
IDLTOUT
R
6
0
ABORT
R
5
0
DTREQ
Rev. 1.1
R
4
0
Function
LININT
R
3
0
ERROR
R
2
0
WAKEUP
R
1
0
DONE
R
0
0