MAX110EVC32-DIP Maxim Integrated Products, MAX110EVC32-DIP Datasheet - Page 6

no-image

MAX110EVC32-DIP

Manufacturer Part Number
MAX110EVC32-DIP
Description
EVAL KIT FOR MAX110
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX110EVC32-DIP

Number Of Adc's
1
Number Of Bits
14
Sampling Rate (per Second)
50
Data Interface
Serial
Inputs Per Adc
2 Differential
Input Range
±VREF
Power (typ) @ Conditions
4.35mW @ 50SPS
Voltage Supply Source
Single Supply
Operating Temperature
0°C ~ 70°C
Utilized Ic / Part
MAX110, MAX111
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MAX110 Control Panel screen displays the current
and average values for the MAX110’s two input chan-
nels, and offers convenient control of the configuration
settings. Pressing TAB selects a switch, and SPACE
BAR manipulates the switch. The “1” and “2” keys
enable and disable polling for inputs 1 and 2, respec-
tively. The input values may be displayed as raw ADC
counts or as real voltages. Data logging can be
enabled if the program is started with the log file com-
mand-line option. Table 6 lists the commands available
in the Control Panel screen.
The MAX110 Shutdown Power Cycling screen allows
evaluation of the shutdown mode. The “D” command
puts the MAX110 into its shutdown state, the “U” com-
mand brings the MAX110 out of shutdown, and the “P”
command makes the program alternate between the
shutdown and active states. Refer to the section
Activating Shutdown Mode.
MAX110 Evaluation System/Evaluation Kit
6
Table 3. Command-Line Options
CONTINUE
OPTION
-Lmyfile
_______________________________________________________________________________________
+O
-O
-V
-A
?
1
2
3
4
Display program version and list of command-
line options.
Specify the reference voltage ("-V2.5" means 2.5
volts).
Specify the size of the rolling average queue
("-A10" means average the last 10 readings).
Allow the bar graph to display overrange values
correctly.
Do not compensate the bar-graph display for
overrange values. Values beyond ±VREF will
display incorrectly due to code aliasing.
Default to COM1.
Default to COM2.
Default to COM3.
Default to COM4.
Specify log file "myfile" to store control-panel
readings.
Assume that the RAM resident program is
already loaded.
FUNCTION
Table 6. Control Panel Commands
Table 5. Terminal Screen Commands
Table 4. Opening Screen Commands
SPACE BAR Toggle the highlighted switch.
SHIFT+TAB
ALT+C
ALT+B
ALT+R
ALT+P
ALT+L
ALT+1
ALT+2
ALT+4
ALT+9
ALT+X
ALT+X
SPACE BAR
KEY
KEY
TAB
C
ENTER
1
2
V
L
S
B
ALT+X
KEY
Return to Opening screen to select a different
COM port.
Begin downloading code to 80C32.
Start the Control Panel screen.
Display the baud-rate menu.
Use 1200 baud.
Use 2400 baud.
Use 4800 baud.
Use 9600 baud.
Send the cold-restart command to 80C32.
Exit the program.
Highlight the next switch.
Highlight the previous switch.
Enable or disable polling of input 1.
Enable or disable polling of input 2.
Display readings as raw ADC counts.
Display readings as real voltages.
Enable or disable data logging. This command
is available only if the MAX110 program was
started with the -L command-line option.
Enter the Shutdown Power Cycling screen.
Enter the Bit Manipulation Panel screen.
Exit the program.
Select next serial port
Use the selected serial port.
Exit the program.
FUNCTION
FUNCTION
FUNCTION

Related parts for MAX110EVC32-DIP