STEVAL-IAS001V1 STMicroelectronics, STEVAL-IAS001V1 Datasheet - Page 11

BOARD EVAL ST7FLITE39/STM1403

STEVAL-IAS001V1

Manufacturer Part Number
STEVAL-IAS001V1
Description
BOARD EVAL ST7FLITE39/STM1403
Manufacturer
STMicroelectronics
Datasheets

Specifications of STEVAL-IAS001V1

Main Purpose
Reference Design, Security Keypad (MCU Based)
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ST7FLITE39, STM1403
Primary Attributes
4x3 Key Matrix, Intrusion Detection
Secondary Attributes
Graphical User Interface, RS-232 Interface
Processor To Be Evaluated
ST7LITE39F2
Interface Type
RS-232
Silicon Manufacturer
ST Micro
Silicon Core Number
ST7Lite39F2 And STM1403
Kit Application Type
Reference Design
Application Sub Type
Security Keypad
Kit Contents
Board CD Docs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6398
STEVAL-IAS001V1
UM0408
2.1.3
2.1.4
2.1.5
Note:
2.1.6
Valid user code
A valid user code is 5-digit long. You cannot use "00000" as a code; it is reserved for the
system default setting.
A total of 49 user codes are supported by the system.
Door open
Each valid user code entry is presented by the magnetic lock LED (yellow) glowing (see
Figure
If another command is issued during the door open condition, the new command will
override and the system will perform accordingly.
All these events are logged in the EEPROM and can be seen through the GUI.
Figure 11. Door open condition
Physical intrusion
The system has been designed to detect physical tampering. Four jumpers have been
provided on the board that determine the tamper condition.
There can be various cases of tampering based on the 4 jumper settings. All are supported
by the system and the buzzer is always on, in the event of tampering.
For details on the tamper detection circuit and design refer to STM1403 data sheet.
Error conditions in user mode
There are various error states for this system, as explained below. For each of the errors
encountered the red error LED glows (see
Normal or no tampering condition
This is the default status, when both the NL jumpers (JP2, JP4) are closed and both the
NH jumpers (JP1, JP3) are open. The buzzer is off.
Tampering - normal low
This is the tamper condition when either or both of the NL jumpers (JP2, JP4) are open
and both the NH jumpers (JP1, JP3) are open. The buzzer is on.
Tampering - normal high
This is the tamper condition when both the NL jumpers (JP2, JP4) are closed and
either or both of the NH jumpers (JP1, JP3) are closed. The buzzer is on.
11). The door remains open for approximately 15 seconds.
ON
Figure
ON
12) for approximately 4-5 seconds.
Running the security door application
11/27