IS-DEV KIT-6C NKK Switches, IS-DEV KIT-6C Datasheet - Page 11

KIT DEV LCD 64X32 COMPACT SWITCH

IS-DEV KIT-6C

Manufacturer Part Number
IS-DEV KIT-6C
Description
KIT DEV LCD 64X32 COMPACT SWITCH
Manufacturer
NKK Switches
Series
SmartSwitch™r
Datasheets

Specifications of IS-DEV KIT-6C

Main Purpose
Switches with Programmable Display
Utilized Ic / Part
IS15DSBFP4RGB
Primary Attributes
2 Compact Switches, PC Board with Flash Memory
Secondary Attributes
Power and Programming Connections
Description/function
SMARTSWITCH Development Kit
For Use With
360-2431 - SERIAL CBL RJ11-DB9 FOR DEV KIT360-2430 - POWER SUPPLY 240VAC FOR DEV KIT360-2429 - POWER SUPPLY 120VAC FOR DEV KIT
Lead Free Status / RoHS Status
Not applicable / Not applicable
Embedded
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Smart Switch - High Resolution
Other names
360-2337
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
The controller disables the timers and switch execution upon receiving this command. However, the switches
are still scanned and reported. They are enabled upon reboot/power up or by command from host.
Command to set LED codes
[LED for switch 1] is one byte for LCD 36x24 and two bytes for LCD 64x32 (first byte for on-cycle and second
byte for off cycle).
[LED for switch 2] is one byte for LCD 36x24 and two bytes for LCD 64x32 (first byte for on-cycle and second
byte for off cycle).
Command to transfer from EEPROM to internal RAM by Addresses
[Address for Switch 1] is one byte with value of 00H to FFH.
[Address for Switch 2] is one byte with value of 00H to FFH.
Command to transfer from EEPROM to internal RAM for one Address
[LCD Module #] is the switch number (31H for switch 1, 32H for switch 2)
[Address] is one byte with value of 01H to FFH.
IS-Dev Kit-5 and IS-Dev Kit-6 Users Manual A.doc
This command sets the LED backlights according to the command’s LED codes.
Example: The following hex string makes switch 1 display green for “ON/OFF CYCLE” and switch 2
display white for ‘ON CYCLE’ and red for “OFF CYCLE”
This command transfers the data from EEPROM to internal RAM according to the addresses. If either of
the address values is zero no transfer takes place for that address.
Example: The following hex string makes switch 1 display the data from location 5 and makes switch 2
display the data from location 6. 2D 00 3035 3036
This command updates the specified switch with the data from EEPROM using the address.
command format: 2CH
transmit format:
command format: 2DH
transmit format:
command format: 2EH [LCD Module #] [Address]
transmit format:
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
For LCD 36x24 mode
2C 00 3232 3137
(xxH) (xxAH)
(xxH) (xxH)
(xxH)
IS-Dev Kit-5 and IS-Dev Kit-6 Users
www.nkkswitches.com • Email engineering@nkkswitches.com
00H
00H
(31H or 32H)
[Address for Switch 1] [Address for Switch 2]
[LED for Switch 1] [LED for Switch 2]
(xxAH)
(xxAH)
Manual
(xxAH)
For LCD 64x32 mode
2C 00 3333 3333 4646 4233
(xxAH)
(xxAH)
Page 11 of 24
1209