CPD250-4530G POWER ONE, CPD250-4530G Datasheet - Page 14

PWR SUP 250W 3.3/5/12/-12V QUAD

CPD250-4530G

Manufacturer Part Number
CPD250-4530G
Description
PWR SUP 250W 3.3/5/12/-12V QUAD
Manufacturer
POWER ONE
Series
CPDr
Type
Isolatedr
Datasheet

Specifications of CPD250-4530G

Output
5V, 3.3V, ±12V
Number Of Outputs
4
Power (watts)
250W
Mounting Type
Compact PCI®
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
5 VDC @ 40A
2nd Output
3.3 VDC @ 40A
3rd Output
12 VDC @ 5.5A
4th Output
-12 VDC @ 2A
Size / Dimension
6.40" L x 1.60" W x 5.07" H (162.5mm x 40.6mm x 128.7mm)
Power (watts) - Rated
250W
Efficiency
82.2%
Approvals
CE, CSA, cUL, EN, TUV, UL
Output Current
40|40|5.5|2 A
Output Voltage
5|3.3|12|-12 V
Input Voltage
48 V
Output Power
250(Typ) W
Switching Regulator
Yes
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
25 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
20 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
4 A
Package / Case Size
162.5 mm x 128.7 mm x 40.6 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
179-2281
CPD250-4530-G
Fig. 13a
Typical disturbance voltage (peak) at the negative input
according to EN 55022, measured at V
(CPD200-4530).
Fig. 13b
Typical disturbance voltage (peak) at the line input
according to EN 55022, measured at V
(CPA250-4530).
Electromagnetic Emission
Radiated and conducted emissions comply with EN 55011/
55022, class A. In addition, CPD500 and CPA500/550 meet
conducted emissions class B.
BCD20005-G Rev. AF, 18-Aug-10
80
20
dBµV
60
40
dBµV
80
20
60
40
0.2
0.2
CPA250 B30510100 /00239, Peak N, Conducted 0.15 - 30 MHz, Divina, 10-Jan-07
CPD200, B738613, 50807-TU, Peak L, Conducted 0.15 - 30 MHz, Divina, 7-Mar-07
0.5
0.5
1
1
®
2
2
200 – 550 Watt CompactPCI
5
5
i nom
i nom
EN 55022 B
10
10
EN 55022 A
EN 55022 A
EN 55022 B
and I
and I
20 MHz
20 MHz
o nom
o nom
Page 14 of 19
Fig. 13c
Typical disturbance voltage (peak) at the line input
according to EN 55022, measured at V
(CPA500-4530).
Fig. 14
Typical radiated electromagnetic field strength (quasi
peak) according to EN 55022, normalised to a distance of
10 m, measured at V
[dBmV/m]
dBµV
80
20
50
40
60
40
30
20
10
0.2
®
CPA500-4530S211 V107 W0622, Vi=230VAC, Ponom, Peak, Phase, Uster, 20-Sep-07
AC-DC and DC-DC Converters
0.5
CPA, CPD Series Data Sheet
i nom
1
and I
2
o nom
.
5
i nom
www.power-one.com
EN 55022 A
EN 55022 B
EN 55022 B
10
and I
EN 55022 A
o nom
20 MHz
[MHz]

Related parts for CPD250-4530G