Specifications of NLP110CMB

Rohs Status
RoHS non-compliant
Accessory Type
Cover with Mounting Bracket
For Use With/related Products
NLP110 Artesyn Power Supplies
NLP110 Series
M o u n t i n g b r a c k e t a c c e s s o r y k i t
The NLP110 series is available with a mounting bracket accessory kit to
facilitate easy customer installation. The mounting bracket has vertical and
horizontal mounting holes and comes complete with mounting and grounding
screws plus an insulator. An installation sheet is also supplied to allow
straightforward customer installation to their system. The mounting bracket can
be used with or without the NLP110 cover. Both the mounting bracket and
cover kits are sold as separate items to retain their inherent flexibility. Details of
the cover assembly kit are available on our website. The NLP110 mounting
bracket is easy to install and is suitable for applications that require power
supply installation options without any additional mechanical work for the
system designer.
MOUNTING BRACKET KIT
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
(#6-32x3/16, P/N 6050111-0000)
Bracket (P/N 5000168-00)
Mounting bracket with screws and insulator
Vertical and horizontal mounting positions
Easy to install
Complies with UL and VDE safety standards *
Cover kit also available
Customer Ground Screw
Insulator (P/N 6210097-00)
NLP110 Power Supply
Mounting Screw
(Size 6-32)
ALL DIMENSIONS IN INCHES (MM)
Customer Horizontal
Mounting Location
(4, #6-32 Holes)
Customer Vertical
Mounting Location
(4, #6-32 Holes)
MODEL NUMBER: NLP110MB
Materials
1
1
4
1
Assembly Notes
1
2
3
4
5
6
7
* When installed follow the ‘installation instructions’.
Mounting bracket
Insulator
Mounting screws #6-32 x 3/16 inch
Installation instructions
Before assembly, ensure unit was turned off for at
least 10 minutes.
Ensure that the insulator is correctly fitted in the
customer chassis under the PCB to maintain safety
creepage and clearances.
Position the power supply onto the bracket aligning
the PCB assembly mounting holes with the 4 stand-
offs on the bracket. Orientation of PCB assembly
relative to the bracket must be as shown in the
drawing opposite.
Secure 4 screws through the holes as shown.
There are 2 customer mounting options:
4 #6-32 holes for horizontal mounting
4 #6-32 holes for vertical mounting
‘Earth’* grounding can be:
(a) Through system chassis when system chassis
(b) Through power supply cover. Connect ‘earth’
When a cover or other sheetmetal option is added, it
is the user’s responsibility to ensure that the
requirements of the relevant safety agency, or
agencies, are complied with.
connected to the ‘earth’.
to cover as shown on drawing opposite.
File Name: NLP110MB.PDF Rev: 06 Mar 2000