Page 1
LPS250 Series 250 Watts Total Power: 250 Watts Input Voltage: 85-264 Vac 120 - 300 Vdc # of Outputs: Single Special Features • Active power factor correction • IEC EN6100-3-2 compliance • Remote sense & remote inhibit • Power fail • Single wire current sharing • Built-in EMI filter • 2:1 Wide range output voltage adjust • 2 Supervisory outputs 5 V and 12 V • Overvoltage protection • ...
Page 2
... DC - OK: TTL logic goes high 50-150 msec after the output. It goes low when there is loss of regulation. Remote sense: Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Environmental Specifications Operating temperature: 0° °C ambient; derate each output at 2.5% per degree from 50° °C Storage temperature: -40 °C to +85 °C Temperature coefficient: ± 0.4% per °C Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min ...
Page 3
... Molex 22-01-3027 PINS: 08-50-0114 SK5 Molex 22-01-3027 PINS: 08-50-0114 SK7 Molex 22-01-3027 PINS: 08-50-0114 Emerson Network Power Connector Kit #70-841-005, includes all of the above 1. Specifications subject to change without notice All dimensions in inches (mm), tolerance is ± 0.02” (± 0.5mm) 3. Specifications are at factory settings enable normally closed remote inhibit, cut jumper J1. 5. Mounting maximum insertion depth is 0.12”. 6. Warranty: 2 year 7. Weight: 2 1.19 kg ...