412-59586-G POWER ONE, 412-59586-G Datasheet - Page 2

COVER FOR MAP130 SERIES

412-59586-G

Manufacturer Part Number
412-59586-G
Description
COVER FOR MAP130 SERIES
Manufacturer
POWER ONE
Series
MAP130r
Type
Coversr
Datasheet

Specifications of 412-59586-G

Accessory Type
Cover
Product
Kits
For Use With/related Products
Power One MAP130 Series Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
179-2297
Multiple Output Model Selection (Cont.)
NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.).
Input Specifications
PARAMETER
Input Voltage- AC
Input Frequency
Brown out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
MCD10115 Rev. 1.3, 05-Feb-10
MODEL
MAP130-4003
MAP130-4004
MAP130-4010
MAP130-4020
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
VOLTAGE
OUTPUT
+15V
+24V
+15V
+12V
+12V
-15V
-15V
-12V
-12V
+5V
+5V
+5V
+5V
-5V
-5V
-5V
4.75V to 5.50V
14.0V to 16.0V
4.75V to 5.50V
23.0V to 25.0V
4.75V to 5.50V
11.5V to 12.8V
4.75V to 5.50V
11.5V to 12.8V
ADJUSTMENT
CONDITIONS/DESCRIPTION
Auto-ranging.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (115 VAC).
90 VAC, 130W load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C.
Switching frequency of main transformer (variable).
CONDITIONS/DESCRIPTION
Full Load, 115VAC. Varies with distribution of loads among outputs.
MAP130-1012.
MAP130-1024.
MAP130-1005 and all multiple output models, main channel only.
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on / turn-off
Varies by output, Total regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to 100% load.
Recovery time to within 1% of initial set point due to a 50-100% load change,
4% max. deviation. (Main output only on multi-output units)
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
CURRENT
OUTPUT
3.5A
20A
20A
20A
20A
4A
1A
1A
1A
1A
5A
1A
3A
5A
1A
3A
130W Continuous Output Power
Page 2 of 4
PEAK CURRENT
(NOTE 1)
30A
30A
30A
10A
30A
10A
8A
1A
1A
5A
1A
1A
1A
3A
1A
3A
MAP130 AC-DC Series Data Sheet
REGULATION
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
LINE
1%
1%
2%
2%
Low Range
High Range
130W load:
Range:
REGULATION
LOAD
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
1.25
0.63
3.00
175
MIN
MIN
90
47
90
40
16
71
See Model Selection Chart
See Model Selection Chart
NOISE %p-p (NOTE 2)
TYPICAL RIPPLE &
NOM
115
230
NOM
3.3
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
MAX
132
264
120
MAX
130
165
500
63
38
80
20
-14.7V to -15.3V
-14.5V to -15.5V
-11.6V to -12.4V
-11.6V to -12.4V
11.75V to 12.0V
11.75V to 12.0V
1
2
15.0V to 15.1V
23.9V to 24.1V
14.5V to 15.5V
INITIAL SETTING
-4.8V to -5.2V
-4.8V to -5.2V
-4.8V to -5.2V
5.15V to 5.2V
5.1V to 5.25V
5.1V to 5.25V
5.1V to 5.2V
ACCURACY
Amps
Watts
UNITS
UNITS
A
VAC
VAC
mS
A
kHz
Sec
mS
µS
Hz
RMS
%
%
PK

Related parts for 412-59586-G