5.2.3 Alphabetical function list
Table 5-4 separates the function in alphabetical order.
Table 5-4: Alphabetical function list
5.3
eos
or
eos
echo [bool]<
echo on/off
onl on/off
spign on/off
spset modes
srqen mask
stat options
xon modes
eos modes, eoschar
[X[B]eoschar]<
D<
COMMAND FUNCTION SYNTAX
CR
>
CR
>
CR
>
Echo characters received from serial port
Change or disable GPIB end-of-string termination mode
Place the GP485 serial port online/offline
Ignore serial port errors
Change serial port parameters
Set conditions for asserting SRQ
Return GP485 status
Change serial port Xon/Xoff protocol
Use in a debugging environment, when a terminal is connected to the GP485
instead of serial device. Data that the GP485 would send to the power-supply
is displayed on the terminal screen. User can also write characters on the
terminal to send to the GP485.
bool= 0 echo off
* call echo without argument, returns it’s current status.
* echo is disabled by default.
* echo remains in effect until echo called again, call nl or turn off the GP485.
Example:
1. WRT$=”echo 1”+CHR$(13)
2. WRT$=”echo”+CHR$(13)
Use
the data string sent by the serial device when the string contains the specified
end-of-string character.
eos
address and is sending serial data to the GPIB.
X,B - set
when sending data from the power-supply.
D - EOS mode disable.
* EOS mode is diabled by default.
* call
* The assignment made by this function remains in effect until
Example:
1. WRT$=”EOS X,B,10”+CHR$(13)
2. WRT$=”eos”+CHR$(13)
Note: The Zup power supply series default termination is <LF> therefore
again, call nl or turn off the GP485.
CALL IBWRT(GP485%, WRT$)
CALL IBWRT(GP485%, WRT$)
CALL IBRD(GP485%, RESP$)
CALL IBWRT(GP485%, WRT$)
CALL IBWRT(GP485%, WRT$)
CALL IBRD(GP485%, RESP$)
eos
applies only when the GP485 has received the serial power-supply talk
eos
Example1 should be performed at each power-on of the GP485.
1 echo on
EOI
to enable the GP485 to assert
without an argument returns it’s current status.
o
* with eos (XEOS) and compare all 8 bits of EOS bytes (BIN)
‘echoing
‘RESP$ contains 1<CR><LF>
‘Enable character
‘What is the current status?
‘X,B,10<CR><LF>
‘send EOI with <CR>
‘RESP$ contains
‘compare 8 bit
‘What is the current status?
EOI
* and add GPIB END message to
o
Table 5-5: functions syntax
eos
called