NLP65-7620G Emerson Network Power, NLP65-7620G Datasheet

no-image

NLP65-7620G

Manufacturer Part Number
NLP65-7620G
Description
PS SWITCHER 5/24V 65W GRND CHOKE
Manufacturer
Emerson Network Power
Series
NLP65r
Datasheet

Specifications of NLP65-7620G

Rohs Status
RoHS non-compliant
Voltage - Output
5V, 24V
Number Of Outputs
2
Power (watts)
65W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 7A
2nd Output
24 VDC @ 2A
Size / Dimension
5" L x 3" W x 1.26" H (127mm x 76.2mm x 32mm)
Power (watts) - Rated
65W
Operating Temperature
0°C ~ 70°C
Efficiency
72%
Approvals
CSA, UL, VDE
Line Regulation
±2%, ±5%
Load Regulation
±2%, ±5%
3rd Output
-
4th Output
-
NLP65 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
The NLP65 series is a 65W universal input AC/DC power supply on a 5 x 3 inch card with a
maximum component height of 1.26 inches for use in 1U applications. Each model has the option
of input harmonic current correction in the same package size making the series ideal for product
designs that will need to comply with EN61000-3-2 legislation. The NLP65 provides 65W of
output power with free air convection cooling which can be boosted to 75W with 20CFM of air.
The NLP65, with full international safety approval and the CE mark, meets conducted emissions
EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The series is
available in a factory installed enclosure with an IEC connector and output connector on flying
leads plus a cover kit for self-installation is also available as an accessory. The NLP65 series is
designed for use in low power data networking, computer and telecom applications such as hubs,
routers, POS terminals, internet servers, cable modems and PABX’s. This list is not exclusive as
the generic feature set of the NLP65 series with industry standard output configurations provides
a solution for most low power applications including many industrial applications.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
OUTPUT SPECIFICATIONS
Total regulation
(Line and load)
Rise time
Transient response
Temperature coefficient
Overvoltage protection
Short circuit protection
Minimum output current
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Input surge current
(cold start)
Safety ground
leakage current
Input current
Input fuse
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
5.0 x 3.0 inch card and 1.26 inch package (1U applications)
Smallest industry standard package
EN61000-3-2 compliance option (HCC)
Overvoltage and short circuit protection
65W with free air convection cooling
EN55022, EN55011 conducted emissions level B
EN61000-4-2,-3,-4, -5, -6 immunity compliant
Enclosure and cover kit options
Main output
Auxiliary outputs
At turn-on
Main output
25% step
at 0.1A/µs
Main outputs
Cyclic operation
Single and multiple
Universal input,
(See Note 2)
NLP65-76xx
version only
120VAC
230VAC
120VAC, 60Hz
230VAC, 50Hz
120VAC, with PFC
230VAC, with PFC
120VAC, without PFC
230VAC, without PFC
UL/IEC127
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
(11,12)
max. dev., 1ms max.
250VAC S 3.15A
5.0% or 250mV
recovery to 1%
120 to 370VDC
Perf. criteria 1
Perf. criteria 1
85 to 264VAC
47Hz to 63Hz
125%, ±10%
(See Note 6)
Continuous
±0.02%/°C
1.0s, max.
1.05A rms
0.51A rms
1.40A rms
0.80A rms
17A max.
32A max.
Level B
Level A
±2.0%
±5.0%
0.7mA
1.4mA
65-75W AC/DC Universal Input Switch Mode Power Supplies
EMC CHARACTERISTICS (continued)
Surge
Fast transients
Radiated immunity
Conducted immunity
GENERAL SPECIFICATIONS
Hold-up time
Efficiency
Isolation voltage
Switching frequency
Approvals and
standards
(See Notes 9, 13)
Weight
MTBF
GENERAL SPECIFICATIONS
Thermal performance
(See Notes 1, 3, 10)
Relative humidity
Altitude
Vibration (See Note 5)
Shock
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
120VAC, 60Hz
230VAC, 50Hz
120VAC, 65W
Input/output
Input/chassis
Fixed
MIL-HDBK-217F
Operating ambient,
(See derating curve)
Non-operating
50°C to 70°C ambient,
convection cooled
0°C to 50°C, ambient,
convection cooled
0°C to 50°C ambient,
20CFM forced air (See Note 10)
Peak (0°C to +50°C, 60s)
Non-condensing
Operating
Non-operating
5Hz to 500Hz
per MIL-STD-810E
File Name: NLP65.PDF Rev: 15 Jan 2002
SPECIFICATIONS
(11,12)
IEC950, UL1950, BABT
2 YEAR WARRANTY
EN60950, VDE0805
CSA C22.2 No. 950
150,000 hours min.
10,000 feet max.
30,000 feet max.
-40°C to +85°C
100kHz, ±5kHz
5% to 95% RH
2.4G rms peak
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
0°C to +70°C
16ms @ 65W
78ms @ 65W
516.4 Part IV
283g (10 oz)
72% typical
50% load
See table
3000VAC
1500VAC
Derate to
65W
75W
1

Related parts for NLP65-7620G

NLP65-7620G Summary of contents

Page 1

... Enclosure and cover kit options The NLP65 series is a 65W universal input AC/DC power supply inch card with a maximum component height of 1.26 inches for use in 1U applications. Each model has the option of input harmonic current correction in the same package size making the series ideal for product designs that will need to comply with EN61000-3-2 legislation ...

Page 2

... Please contact the applications group at Artesyn for assistance with EMI compliance. 12 The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option. J2, L6 and JP10 are included safety agency approved grounding pin ground choke and JP10 is a jumper. This option is intended for use in non-metallic chassis applications where grounding is not possible via the mounting screws ...

Page 3

... V (B) V (B) V (A) V (A) V (A) V (A) Return Return Return Return N/C V (C) DERATING CURVE Output Power (Watts) 20 CFM FORCED AIR COOLING NATURAL 38W CONVECTION 32W COOLING 0˚C 10˚C 20˚C 30˚C 40˚C 50˚C 60˚C 70˚C www.artesyn.com File Name: NLP65.PDF Rev: 15 Jan 2002 3 ...

Related keywords