SBLP65-1012G POWER ONE, SBLP65-1012G Datasheet - Page 3

POWER SUP 65W 12V 6.25A OUTPUT

SBLP65-1012G

Manufacturer Part Number
SBLP65-1012G
Description
POWER SUP 65W 12V 6.25A OUTPUT
Manufacturer
POWER ONE
Series
SBLP65r
Datasheet

Specifications of SBLP65-1012G

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
65W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 6.25A
Size / Dimension
4" L x 2" W x 1.3" H (101.6mm x 50.8mm x 33mm)
Power (watts) - Rated
65W
Operating Temperature
-10°C ~ 70°C
Efficiency
80%
Approvals
CSA, EN, TUV, UL
Line Regulation
±2%
Load Regulation
±2%
Output Current (max)
5A
Input Voltage
90 to 264V
Output Voltage
12V
Output Power (max)
60W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
101.6mm
Product Height (mm)
33.02mm
Product Depth (mm)
50.8mm
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
8
Product
Switching
Commercial/medical
Commercial
Output Power Rating
60 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
5 A
Dimensions
4 in L x 2 in W x 1.3 in H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2381
Output Specifications
Fault Protection
MCD10023 Rev. 1.8, 30-Jun-09
1
Output power
Output DC voltages
Output DC current
Minimum load
Leakage current
Output ripple & noise
Overshoot
Load transient
Turn-On & Turn-Off
characteristics
Turn-on Delay
Turn-on Rise Time
Hold-up Time
Remote Sense
Control loop stability
Current Limit
Protection
Short-circuit Protection
OVP Trip
See Model Selection table.
Parameter
Parameter
With convection cooling
With 3 CFM forced-air cooling for single output
models
Vo1 output is adjustable -5/+10 % of nominal
Required to meet total regulation
At 264 VAC/60 Hz
Vo1 overshoot at turn-on
Vo1 deviation due to a 50 to 100%
load change at a rate of 1A/µs
Outputs turn ON monotonically at minimum
output current or at full load.
Outputs turn OFF monotonically at minimum
output current or at full load.
Time required for output within regulation after
initial application of AC input @ 90 VAC.
Time required for output voltage to rise from
10% to 90%.
Time Vo1 is required to stay within 95%
regulation after removal of AC measure from
the last peak of the AC line at 120 VAC and
max power.
Maximum compensation.
Phase margin.
Gain margin.
Protection is provided.
Provided with auto-recovery.
Vo1, 3.3 V
Vo1, 5 V
Vo1, 12 V
Vo1, 24 V
Vo1, 48 V
Conditions/Description
Conditions/Description
SBLP65 AC-DC Single-Output Series Data Sheet
Page 3 of 6
Min.
Min.
3.6
5.6
45
16
10
14
29
55
1
1
Nom.
Nom.
15.35
3.75
31.6
57.5
6.2
www.power-one.com
Max.
Max.
0.75
3.95
16.7
34.2
500
6.9
60
65
±5
20
60
5
3
1
1
1
65 Watts
Degrees
Units
Watts
Units
pk-pk
ADC
VDC
Sec
mA
mV
mV
ms
ms
dB
%
%
A
A

Related parts for SBLP65-1012G