MPU150-4530 POWER ONE, MPU150-4530 Datasheet - Page 3

no-image

MPU150-4530

Manufacturer Part Number
MPU150-4530
Description
PWR SUP QUAD OUT +5,+3.3,12,12V
Manufacturer
POWER ONE
Series
MPU150r
Type
Commercialr
Datasheets

Specifications of MPU150-4530

Voltage - Output
3.3V, 5V, 12V, 12V
Number Of Outputs
4
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5.1 VDC @ 30A
2nd Output
3.3 VDC @ 15A
3rd Output
12 VDC @ 3A
4th Output
12 VDC @ 3A
Size / Dimension
8" L x 4.2" W x 1.5" H (203.2mm x 106.7mm x 38.1mm)
Power (watts) - Rated
150W
Operating Temperature
0°C ~ 50°C
Efficiency
75%
Approvals
CSA, EN, TUV, UL
Line Regulation
0.4%, 0.6%
Load Regulation
1%, 1.5%, 7%
Product
Switching
Commercial/medical
Commercial
Output Power Rating
150 W
Input Voltage
85 VAC to 264 VAC
Output Voltage (channel 1)
5 V
Output Current (channel 1)
30 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
15 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
3 A
Mounting Style
Chassis
Dimensions
8 in L x 4.2 in W x 1.5 in H
Brand/series
MPU150 Series
Configuration
Open-Frame
Current, Input
3 A (RMS) (Max.)
Current, Leakage
22 mA (Max.) @ Dual Output MPU150, 264 VAC
Hold Time
20 ms (Min.)
Operation
Switching
Output
+3.3 VDC @ 15 A, +5 VDC @ 30 A, 12 VDC @ 3 A, 12 VDC @ 3 A
Power, Output
150 W
Power, Rating
150 W (Nom.)
Primary Type
AC-DC
Special Features
PFC, Remote Sense
Temperature, Operating
0 to +50 °C @ 100 % Load
Voltage, Input
85 to 264 VAC
Voltage, Output
+3.3, +5, 12, 12 VDC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
179-2018
MCD10009 Rev. 1.0, 15-Oct-07
MDU150 Input Specifications
PARAMETER
Input Voltage - DC
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Operating Frequency
Inrush Current
Output Specifications
PARAMETER
Efficiency
Minimum Load, V1
Minimum Load, V3
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
NOTES: 1) This product is not rated for convection applications.
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Output Good Signal,
Low to High Transition
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
CONDITIONS/DESCRIPTION
Continuous input range.
Lowest DC input voltage that regulation is maintained with full rated loads.
At 150 watts, over DC input range.
36 VDC at full rated load.
Non-user serviceable internally located AC input line fuse.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Consult factory.
CONDITIONS/DESCRIPTION
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
Minimum load required to maintain regulation on,
V2 at maximum load.
Minimum load required on single output models.
Minimum load required to maintain regulation on
V4 at maximum load.
Full load, 20 MHz bandwidth.
With 300 LFM forced air cooling. (Note 1)
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Latch style overvoltage protection. Available on
V1, V2, all models, and V3 on all models except
MPU150-3300.
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
TTL compatible signal available for V1. Pull-up resistor is 10k . Signal
is high when output is above the specified limits. Signal shall remain low
for 20 milliseconds following loss of Output Good.
TTL compatible logic signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
Accuracy of shared current with up to 6 parallel units. Single wire current share
on V1 and V2 with return via -Sense return.
Available on V1 and V2. Total voltage compensation for cable losses with
respect to the main output.
Output voltage is inhibited by application of an external high (5V) signal.
Page 3 of 6
MPU150-4350G 3.3V output, V1
MPU150/MDU150 Series Data Sheet
Single output models V1
Triple output models V1
Triple output models V3
Quad output models V1
Quad output models V3
MPU150-S259 12V
MPU150-S262 24V
MPU150-S261 48V
MPU150-S259 V1
MPU150-S262 V1
MPU150-S261 V1
5V output, V1, V2
2.5V output, V1
3.3V output, V1
3.3V output, V2
12V output, V2
12V output, V3
3.3V
5V
17.0
32.0
58.0
3.16
4.75
10.5
21.5
43.0
MIN
MIN
MIN
0.3
3.0
4.1
3.8
6.0
4.3
36
34
20
65
14
14
4
3
0
0
0
5
See Model Selection Charts
See Model Selection Charts
NOM
NOM
NOM
100
150
500
70
75
50
10
3
2
www.power-one.com
3.25
4.65
4.65
20.5
38.0
62.7
3.25
4.90
11.9
23.5
47.0
MAX
MAX
MAX
500
6.4
4.2
6.4
75
16
19
5
A
Watts
UNITS
UNITS
UNITS
VDC
VDC
kHz
mV
ms
RMS
ms
ms
%
%
µs
%
A
A
V
V
s

Related parts for MPU150-4530