NTS353 Emerson Network Power, NTS353 Datasheet

POWER SUPPLY 350W 12V OUT

NTS353

Manufacturer Part Number
NTS353
Description
POWER SUPPLY 350W 12V OUT
Manufacturer
Emerson Network Power
Series
NTS350r
Type
Open Framer
Datasheets

Specifications of NTS353

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
350W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 16.6A
Size / Dimension
7" L x 4" W x 1.5" H (177.8mm x 101.6mm x 38.1mm)
Power (watts) - Rated
350W
Operating Temperature
0°C ~ 50°C
Efficiency
85%
Approvals
AUSTEL, CB, CE, CSA, NEMKO, TUV, UL
Line Regulation
±2%
Load Regulation
±2%
No. Of Outputs
1
Output Voltage
12V
Output Current
16.6A
Power Rating
350W
Input Voltage
85V AC To 264V AC
Output Type
Fixed
Output Current 1
16.6A
Input Frequency
47 to 440Hz
Screening Level
Commercial
Product Length (mm)
177.8mm
Product Height (mm)
38.1mm
Product Depth (mm)
101.6mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
15
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1168

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NTS353
Manufacturer:
NS
Quantity:
1 000
Special Features
Safety
Total Power:
Input Voltage:
# of Outputs:
NTS350 Series
350 Watts
Active power factor correction
IEC EN6100-3-2 compliance
Remote sense
Power fail and remote inhibit
Single wire current sharing
Built-in EMI filter
Low output ripple
5V standby
12V fan output
Overvoltage protection
Overload protection
Thermal overload protection
DC power good
Built in OR-ing diode / FET
Optional fan cover (-CF suffix)
TUV
UL
CSA
NEMKO
AUSTEL
CB
CE
60950
0950
60950
60950
60950
Certificate and report
Mark (LVD)
200 - 350 Watts
85 - 264 VAC
120 - 300VDC
Single
Electrical Specifications
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Safety ground leakage
current
Output
Maximum power
Adjustment range
Standby output
Fan output
Hold-up time
Overload protection
Overvoltage protection 20-35% above nominal output
85 - 264 VAC (wide range)
47-440 Hz
38A max., cold start @ 25°C
85% typical at full load
FCC Class B conducted and radiated; CISPR22 Class B conducted and radi-
ated; EN55022 Class B conducted and radiated; VDE0878PT3 Class B con-
ducted and radiated.
<0.5mA @ 50/60 Hz, 264 VAC input
200W for convection; 350W with 30CFM forced air
±5%
5V @ 2A regulated, ±5%
12 V @ 1A, -5 %, +7%, 0.5A for -CF version
20 ms @ 350 W load, 115 VAC nominal line at factory voltage setting
Short circuit protection on all outputs. Case overload protected @ 115-
130% above peak rating
Embedded Power for
Business-Critical Continuity
NTS350 Series
Rev. 11.24.08
1 of 3

Related parts for NTS353

NTS353 Summary of contents

Page 1

NTS350 Series 350 Watts Total Power: 200 - 350 Watts Input Voltage 264 VAC 120 - 300VDC # of Outputs: Single Special Features • Active power factor correction • IEC EN6100-3-2 compliance • Remote sense • Power fail ...

Page 2

... Hz, operational MTBF demonstrated 1M hours at full load and 25°C ambient conditions Ordering Information Maximum Load Model Output Minimum with Convection Number Voltage Load Cooling NTS353 12V 0A NTS355 24V 0A NTS358 48V 0A NTS359 54V 0A 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. ...

Page 3

... Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. ...

Related keywords