PWR SUPPLY 110W 5/12/12/24V

LPQ114

Manufacturer Part Number
LPQ114
Description
PWR SUPPLY 110W 5/12/12/24V
Manufacturer
Emerson Network Power
Series
LPQ110r
Datasheet

Specifications of LPQ114

Voltage - Output
5V, ±12V, 24V
Number Of Outputs
4
Power (watts)
110W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 9A
2nd Output
12 VDC @ 4.5A
3rd Output
-12 VDC @ 700mA
4th Output
24 VDC @ 3.5A
Size / Dimension
4" L x 7" W x 1.8" H (101.6mm x 177.8mm x 45.7mm)
Power (watts) - Rated
110W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CB, CE, CSA, NEMKO, UL, VDE
Line Regulation
±2%; ±3%; ±5%; 10%, -5%
Load Regulation
±2%; ±3%; ±5%; 10%, -5%
Product
Switching
Output Power Rating
110 W
Input Voltage
85 VAC to 264 VAC
Output Voltage (channel 1)
5 V
Output Current (channel 1)
9 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
4.5 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
0.7 A
Mounting Style
Chassis
Dimensions
7.3 in L x 4.28 in W x 2.2 in H
Open Frame/enclosed
Open Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPQ114
Manufacturer:
EmersonN
Quantity:
45
Part Number:
LPQ114
Manufacturer:
astec
Quantity:
1 000
Part Number:
LPQ114-B
Manufacturer:
EmersonN
Quantity:
1
Part Number:
LPQ114-B
Manufacturer:
VICOR
Quantity:
1 000
Ordering Information
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and
4. 4th output adjustable 5 to 25 V, factory set at 5 V.
5. Minimum loads are required.
Note: -B suffix added to the model number indicates L bracket option.
Environmental Specifications
Number
Logic Control
Power failure
Remote sense
Operating temperature: 0° to 50 °C ambient. Derate each output 2.5% per degree from
Storage temperature:
Temperature coefficient: ± 0.4% per °C
Electromagnetic
susceptibility:
Humidity:
Vibration:
MTBF demonstrated:
LPQ112
LPQ113
LPQ114
Model
settings.
load ranges.
± 5 - 25 V
± 5 - 25 V
Voltage
Output
-12 V
-15 V
-12 V
-12 V
12 V
15 V
12 V
5 V
5 V
5 V
Minimum
Load
0.5 A
2 A
0 A
0 A
0 A
2 A
0 A
0 A
0 A
2 A
0 A
0 A
TTL logic signal goes high 50 - 150 msec after 5 V output. It goes
low at least 4 msec before loss of regulation
C ompensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
50° to 70 °C (except for -C version).
-40 °C to +85 °C
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at
four major resonances 0.75G peak 5Hz to 500Hz, operational
> 550,000 hours at full load and 25 °C ambient conditions
with Convection
Maximum Load
Cooling
4.5 A
0.7 A
2.5 A
4.5 A
0.7 A
2.5 A
4.5 A
0.7 A
3.5 A
9 A
9 A
9 A
Maximum Load
with 30CFM
Forced Air
1.0 A
1.0 A
1.0 A
4.5 A
11 A
11 A
11 A
5 A
3 A
5 A
3 A
5 A
Load 1
Peak
1.5 A
3.5 A
1.5 A
3.5 A
1.5 A
15 A
15 A
15 A
9 A
9 A
9 A
5 A
Regulation 2
+10 / -5%
± 2%
± 3%
± 5%
± 3%
± 2%
± 3%
± 5%
± 3%
± 2%
± 3%
± 5%
240mV, max
240mV, max
Ripple P/P
(PARD) 3
120 mV
120 mV
150 mV
150 mV
120 mV
120 mV
240mV
50 mV
50 mV
50 mV
Mating Connectors
AC Input:
DC Outputs: Molex 09-50-8121 (USA)
Remote
Sense
Power Fail:
Astec Connector Kit #70-841-006, includes all of
the above
1. Specifications subject to change without notice.
2 . All dimensions in inches (mm), tolerance is
3. Specifications are for convection rating at
4. Mounting holes M1 and M2 should be grounded
5. Mounting hole M1 is safety ground connection.
6. L bracket mounting (6-32) maximum insertion
depth is .20” (5).
7. Warranty: 2 year
8. Weight: 1.25 lb./0.57 kg
Pin Assignments
Connector
SK1-1
SK1-3
SK1-5
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK2-7
SK2-8
SK2-9
SK2-10
SK2-11
SK2-12
SK201-1
SK201-2
SK202-1
SK202-2
± 0.02” (± 0.5mm)
factory settings unless otherwise stated.
for EMI purposes.
Embedded Power for
Business-Critical Continuity
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
09-91-1200 (UK)
PINS: 08-58-0111
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
LPQ112
GND
Neutral
Line
+5 V
+5 V
+5 V
Common
Common
Common
Common
+12 V
+12 V
-12 V
+5-25 V
-5-25 V
+sense
-sense
POK
GND
LPQ113
GND
Neutral
Line
+5 V
+5 V
+5 V
Common
Common
Common
Common
+15 V
+15 V
-15 V
+5-25 V
-5-25 V
+sense
-sense
POK
GND
LPQ110 Series
Rev. 08.13.07
LPQ114
GND
Neutral
Line
+5 V
+5 V
+5 V
Common
Common
Common
Common
+12 V
+12 V
-12 V
+24 V
Common
+sense
-sense
POK
GND
2 of 3

Related parts for LPQ114