NFS40-7608J Emerson Network Power, NFS40-7608J Datasheet - Page 2

POWER SUPPLY AC/DC 5.1V@8A 40W

NFS40-7608J

Manufacturer Part Number
NFS40-7608J
Description
POWER SUPPLY AC/DC 5.1V@8A 40W
Manufacturer
Emerson Network Power
Series
NFS40r
Type
Open Framer
Datasheet

Specifications of NFS40-7608J

Voltage - Output
5.1V, ±12V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC, 120 ~ 370VDC
Mounting Type
Chassis Mount
1st Output
5.1 VDC @ 7A
2nd Output
12 VDC @ 3A
3rd Output
-12 VDC @ 1A
Size / Dimension
5" L x 3" W x 1.2" H (127mm x 76.2mm x 30.5mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 70°C
Efficiency
70%
Approvals
CSA, EN, IEC, UL, VDE
Line Regulation
±0.2%
Load Regulation
±2%
Product
Switching
Output Voltage (channel 1)
5.1 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
2 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
0.35 A
Input Voltage
85 to 264V
Output Power (max)
40W
Input Frequency
47 to 440Hz
Screening Level
Commercial
Product Length (mm)
127mm
Product Height (mm)
30.48mm
Product Depth (mm)
76.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
9
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Compliant
Specifications
EMC Charateristics
General Specifications
Environmental Specifications
All specifications are typical at nominal input, full load at 25
Conducted emissions:
Radiated emissions:
ESD air:
ESD contact:
Surge:
Fast transients:
Radiated immunity:
Conducted immunity:
Thermal performance:
(See notes 8, 10)
Relative humidity:
Altitude:
Vibration (See Note 11):
Hold-up time:
Efficiency:
Isolation voltage:
Switching frequency:
Approvals and standards: (see
Notes 9, 13)
Weight:
MTBF demonstrated:
(11, 12)
EN55022, FCC part 15
EN55022
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-2, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
110 Vac, 40 W
230 Vac, 40 W
Input/output
Input/chassis
Variable
VDE0805, EN60950, IEC950, IEC1010,
UL1950, CSA C22.2 No. 950
280 g (9.88 oz)
MIL-HDBK-217E
Operating
Non-operating
50 °C ambient temp.,
convection cooled
Forced air cooling
+50 °C to +70 °C ambient
Peak (60 seconds)
Non-condensing
Operating
Non-operating
5-500 Hz
°
C unless otherwise stated
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
14 ms
110 ms
70% typical
3000 Vac
1500 Vac
170,000 hours
0° C to +70 °C
-40 °C to +85 °C
40 W
50 W @ 20 CFM
Derate linearly to 50% load
60W
5 to 80% RH
10,000 feet max.
40,000 feet max.
2.4 G rms peak
Embedded Power for
Business-Critical Continuity
Rev.02.01.10_65
NFS40 Series
2 of 4

Related parts for NFS40-7608J