MAP140-1048 POWER ONE, MAP140-1048 Datasheet

PWR SUP 140W 48V 3.1A OUTPUT

MAP140-1048

Manufacturer Part Number
MAP140-1048
Description
PWR SUP 140W 48V 3.1A OUTPUT
Manufacturer
POWER ONE
Series
MAP140r
Datasheet

Specifications of MAP140-1048

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
140W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.3A
Size / Dimension
7" L x 4.3" W x 1.8" H (177.8mm x 109.2mm x 45.7mm)
Power (watts) - Rated
140W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CE, CSA, TUV, UL
Line Regulation
0.1%
Load Regulation
0.5%
Product
Switching
Commercial/medical
Commercial
Output Power Rating
110 W
Input Voltage
85 VAC to 264 VAC
Output Voltage (channel 1)
48 V
Output Current (channel 1)
2.3 A
Mounting Style
Chassis
Dimensions
7 in L x 4.3 in W x 1.97 in H
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2011
Single Output Model Selection
MAP140-1012 12V/15V
MAP140-1024 24V/28V
MAP140-1048
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Multiple Output Model Selection
MAP140-3000P +12V
NOTES: 1) Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts.
Description
MCD10167 Rev. 1.0, 04-Jun-10
Power-One’s MAP140 Series provides a full range of options and up to 30 watts more power than comparable
products in this industry-standard footprint. With a universal input from 85 to 264 VAC and power densities up to 2.6
watts/inch3, the MAP140 meets the most rigorous requirements of commercial, industrial, and datacom systems.
Rated for use in convection and forced-air cooled (200 LFM) applications, the MAP140 delivers dependable power
with a Mean Time Between Failures (MTBF) in excess of 180,000 hours. In addition to UL, CSA, and TÜV regulatory
compliance, the MAP140 displays the CE Mark.
MODEL
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation.
3) With 200 LFM forced air cooling.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
VOLTAGE
VOLTAGE
OUTPUT
OUTPUT
-12V
48V
+5V
11.0V to 16.0V
22.8V to 29.2V
45.6V to 54.0V
4.75 - 5.25V
ADJUSTMENT
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
9.2/7.3A (Note 2)
80W Convection Cooled, 140W Forced-Air Cooled (200 LFM)
COOLED CURRENT
CURRENT (NOTE 1)
4.6/4A (Note 2)
CONVECTION
1A/1.5A PK
4A/9A PK
16A/25A
OUTPUT
2.3A
Page 1 of 4
12.5A/10A (Note 2)
6.3A/5.4A (Note 2)
CURRENT (NOTE 3)
CURRENT (NOTE 1)
20A/25A PK
PEAK OUTPUT
1A/1.5A PK
FORCED AIR
4A/9A PK
3.1A
Features
RoHS lead-solder-exemption compliant
Universal input 85-264 VAC
Input transient & ESD compliance to EN61000-4-2/-3/-4
CE marked to Low Voltage Directive
Industry-standard footprint: 7.00" x 4.30" x 1.80"
(177.8mm x 109.2mm x 45.7mm)
Remote sense and overvoltage protection
Power Fail signal standard on MAP140-3000P, optional
on MAP140-1012 and MAP140-1024
Optional overtemperature protection, L-bracket, and cover
MAP140 AC-DC Series Data Sheet
REGULATION
REGULATION
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
LINE
LINE
REGULATION
REGULATION
0.5%
0.5%
0.5%
LOAD
LOAD
1%
2%
2%
RIPPLE & NOISE
RIPPLE & NOISE
%p-p (NOTE 1)
%p-p (NOTE 2)
1%
1%
1%
1%
1%
1%
www.power-one.com
11.97V to 12.03V
23.95V to 24.05V
11.97V to 12.03V
-11.4V to -12.6V
47.9V to 48.1V
5.09V to 5.11V
INITIAL SETTING
INITIAL SETTING
ACCURACY
ACCURACY

Related parts for MAP140-1048

MAP140-1048 Summary of contents

Page 1

... MAP140-1024 24V/28V 22.8V to 29.2V 48V 45.6V to 54.0V MAP140-1048 NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation. 3) With 200 LFM forced air cooling. Multiple Output Model Selection ...

Page 2

... Optional signal provides system shutdown due to excessive internal temperature. See options. MCD10167 Rev. 1.0, 04-Jun-10 MAP140 AC-DC Series Data Sheet 110 watt load: 140 watt load: MAP140-3000P Single output models MAP140-3000P, V1 MAP140-1012 MAP140-1024 MAP140-1048 Page MIN NOM MAX UNITS 85 264 VAC 47 ...

Page 3

... Add ‘P’ suffix to model number. Provides 2.3mS warning time before main output drops 5%. Warning time increases at reduced load levels. Option available only on MAP140-1012 and MAP140-1024. Power fail is standard on MAP140-3000P. Thermal Shutdown Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature condition ...

Page 4

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10167 Rev. 1.0, 04-Jun-10 MAP140 AC-DC Series Data Sheet OVERALL WEIGHT: 1.3 lb (0.59 kg) Page NOTE 1 ...