MPB125-4350RG POWER ONE, MPB125-4350RG Datasheet - Page 3

PWR SUP 125W 3.3/5/12/-12V QUAD

MPB125-4350RG

Manufacturer Part Number
MPB125-4350RG
Description
PWR SUP 125W 3.3/5/12/-12V QUAD
Manufacturer
POWER ONE
Series
MPB125r
Datasheet

Specifications of MPB125-4350RG

Voltage - Output
3.3V, 5V, ±12V
Number Of Outputs
4
Power (watts)
125W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 10A
2nd Output
5 VDC @ 15A
3rd Output
12 VDC @ 5A
4th Output
-12 VDC @ 500mA
Size / Dimension
5" L x 3.8" W x 1.3" H (127mm x 97mm x 31.8mm)
Power (watts) - Rated
125W
Operating Temperature
0°C ~ 50°C
Efficiency
80%
Approvals
CE, CSA, EN, IEC, TUV, UL
Line Regulation
±3%, ±4%, ±5%
Load Regulation
±3%, ±4%, ±5%
Product
Switching
Commercial/medical
Commercial
Output Power Rating
33 W
Input Voltage
90 VAC to 264 VAC
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
10 A
Output Voltage (channel 2)
5 V
Output Current (channel 2)
15 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
5 A
Mounting Style
Chassis
Dimensions
5 in L x 3.8 in W x 1.25 in H
Output Current (max)
10/15/5/0.5A
Output Voltage
3.3/5/12/-12V
Output Power (max)
125W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
127mm
Product Height (mm)
26.9mm
Product Depth (mm)
76.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Pin Count
19
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
179-2279
MPB125-4350R-G
OCT 24, 2005 revised to JUN 05, 2006
Interface Signals and Internal Protection (Cont.)
PARAMETER
Power Good Signal
Power Supply OK Signal
Thermal Shutdown
Current Share
Isolation Diode
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Flicker
Radiated Susceptibility
EFT/Burst
Input Transient Protection
RF Immunity
Magnetic Fields
Voltage Dips
Insulation Resistance
Leakage Current
CONDITIONS/DESCRIPTION
AC/DC indicator - This signal indicates the status of the AC input or DC outputs.
When there is sufficient AC voltage and the outputs are operating normally, an
open collector signal is provided.
Turn-On delay time from application of AC:
Warning time before outputs go out of regulation:
Warning time before outputs deviate ±10% from the nominal value:
Provided on dual-output models. Open collector signal intended to drive an LED.
Closed collector occurs when the Power Good Signal is in its open collector state.
Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
Provided on dual-output models. Up to 4 units can be connected in parallel.
There are some limits for parallel operation. See MPB125 Applications Note.
N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation.
An external diode is required on MPB125-2003 and MPB125-2005 models for
redundancy on both V1 and V2, or when ordering, you can specify MPB125-2003D or
-2005D which have an internal isolation diode.
Internal isolation diode is provided on V1 for all dual-output models except the
MPB125-2003 and MPB125-2005. Specify MPB125-2003D or MPB125-2005D,
respectively, if an internal isolation diode is required for these models.
CONDITIONS/DESCRIPTION
UL60950-1.
CSA 22.2 No. 60950-1.
EN60950 (TÜV).
IEC60950-1.
AC to chassis.
Input to output.
EN55022 Conducted.
Per EN61000-4-2, Level 4
Per EN61000-3-3.
Per EN61000-4-3.
Per EN61000-4-4.
Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave)
Per EN61000-4-8.
Per EN61000-4-11.
Input to output.
Per EN60950 (264 VAC)
MPB125 Multiple-Output AC-DC Series Data Sheet
Page 3 of 9
Sync Current
Pull-up Voltage
Sync Current
Pull-up Voltage
1500
3000
MIN
MIN
50
15
5
B
8
1
NOM
NOM
10
3
3
1
www.power-one.com
MAX
500
MAX
1.0
20
30
20
30
UNITS
UNITS
Class
VDC
VAC
V/m
V/m
A/m
M
ms
mA
mA
mA
kV
kV
V
V

Related parts for MPB125-4350RG