DS550-3 Emerson Network Power, DS550-3 Datasheet - Page 2

POWER SUP 12V 550W 1U X 2U X 11"

DS550-3

Manufacturer Part Number
DS550-3
Description
POWER SUP 12V 550W 1U X 2U X 11"
Manufacturer
Emerson Network Power
Series
DS550r
Datasheet

Specifications of DS550-3

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
550W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 45A
Size / Dimension
11.05" L x 3.07" W x 1.57" H (280.7mm x 78mm x 39.9mm)
Power (watts) - Rated
540W
Operating Temperature
-10°C ~ 50°C
Efficiency
84%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±3%, ±4%, ±5%
Load Regulation
±3%, ±4%, ±5%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
12V
Output Current
45A
Power Rating
550W
Input Voltage
90V AC To 264V AC
Length
305.6mm
Width
78mm
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
40mm
Product Depth (mm)
78mm
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS550-3
Manufacturer:
IXYS
Quantity:
1 000
Environmental Specifications
Operating temperature:
Storage temperature:
Altitude, operating:
Electromagnetic
susceptibility / Input transients:
RoHS & lead-free compliant (no tantalum caps)
Humidity:
Shock and vibration specificatons complies with Emerson Network Power Std. Specification, Q3205
MTBF (Demonstrated):
Logic Control
PS Inhibit:
PS_Status:
AC_Pfail:
Fan_Fault:
Tach_1:
Ordering Information
*Overcurrent latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.
*For 5 Vsb, consult marketing.
DS450-3
DS550-3
Output
Voltage Set Point
Nominal Output
12.0 Vdc
12.0 Vdc
3.3 Vsb
3.3 Vsb
When supply is inserted into the system the pin is pulled LOW and power supply is ON after all other pins are
seated
I
due to -PS_ON, PS_KILL, or a fault, then P6 is high.
I
failure (AC missing or too low for power supply operation). If the supply is turned off due to -PS_ON, PS_KILL,
or a fault, then P7 remains high.
The PSU will provides an open collector Tach 1 output.
This signal is generated from the fan. The signal should generate 2 pulses per revolution. The logic in the
system will be operating at 3.3 V.
2
2
C port P6. When the power supply is on and running normal P6 is low. When the power supply is off, either
C port P7. P7 is high except when the power supply turns the main outputs, not +3.3 Vsb, off due to an AC
-10 °C to 50 °C
-40 °C to +70 °C
10,000 ft.
-EN61000-3-2, -3-3
-EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
-EN55024:1998
20 to 90% RH, non-condensing
400K Hrs at full load, 40 °C
Tolerance
Set Point
± 0.2%
± 0.2%
± 1%
± 1%
Regulation
+5 / -3%
+5 / -4%
+5 / -3%
+5 / -4%
Total
Minimum
Current
0 A
0 A
0 A
0A
Maximum
Current
37.0 A
45.0 A
3.0 A
3.0 A
Output Ripple
120 mV
120 mV
60 mV
60 mV
Embedded Power for
Business-Critical Continuity
P/P
4.9 A Avg, 7 A max
4.9 A Avg, 7 A max
39.5 A - 44.4 A
48.0 A - 54.0 A
Overcurrent
Rev. 03.15.11_82
DS450/DS550
2 of 4

Related parts for DS550-3