HAD15-0.4-AG POWER ONE, HAD15-0.4-AG Datasheet - Page 9

LNR SUP DBL OUT +-15V/.4A OUT

HAD15-0.4-AG

Manufacturer Part Number
HAD15-0.4-AG
Description
LNR SUP DBL OUT +-15V/.4A OUT
Manufacturer
POWER ONE
Series
Linearr
Type
Commercialr
Datasheets

Specifications of HAD15-0.4-AG

Voltage - Output
±15V
Number Of Outputs
2
Power (watts)
6W
Applications
Commercial
Power Supply Type
Linear, Regulated (Open Frame)
Voltage - Input
100, 120, 220, 240VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 400mA
2nd Output
-15 VDC @ 400mA
Size / Dimension
4.87" L x 4.00" W x 2.10" H (123.7mm x 101.6mm x 53.3mm)
Power (watts) - Rated
6W
Operating Temperature
0°C ~ 50°C
Efficiency
55%
Approvals
CE, CSA, EN, IEC, TUV, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Output Current (max)
0.4/0.4A
Output Voltage
15/-15V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
123.7mm
Product Height (mm)
53.34mm
Product Depth (mm)
101.6mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Package / Case
Case B
Product
Linear
Commercial/medical
Commercial
Input Voltage
100 VAC to 264 VAC
Output Voltage (channel 1)
+ 15 V
Output Current (channel 1)
0.4 A
Output Voltage (channel 2)
- 15 V
Output Current (channel 2)
0.4 A
Dimensions
123.7 mm L x 101.6 mm W x 53.34 mm H
Open Frame/enclosed
Open Frame
Application
For use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems
Configuration
Open-Frame
Operation
Linear
Output
-15 VDC @ 0.4 A, +15 VDC @ 0.4 A
Primary Type
AC-DC
Voltage, Input
100 to 264 VAC
Voltage, Output
-15, +15 VDC
Worldwide Ac Input Capabilities
100/120/220/230/240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2306
Linear Power Supplies Data Sheet
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
MCD10016 Rev. 1.2, 13-Nov-09
Page 9 of 9
www.power-one.com

Related parts for HAD15-0.4-AG