PWR SUPPLY 55W 24V OUT SINGLE

BLP55-1024G

Manufacturer Part Number
BLP55-1024G
Description
PWR SUPPLY 55W 24V OUT SINGLE
Manufacturer
POWER ONE
Series
BLP55r
Type
Switchingr
Datasheets

Specifications of BLP55-1024G

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
55W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 250VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 1.6A
Size / Dimension
5" L x 3" W x 1.23" H (127mm x 76.2mm x 31.2mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 70°C
Efficiency
70%
Approvals
CB, CE, CSA, EN, IEC, UL
Line Regulation
±2%
Load Regulation
±2%
Input Voltage
85 to 264 V
Output Voltage
24 V
Maximum Current Rating
1(rms)(Typ) A
Maximum Output Current
1.6 A
Maximum Output Power
40 W
Input Frequency
47 to 63 Hz
Product
Switching
Commercial/medical
Commercial
Output Power Rating
55 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
2.3 A
Mounting Style
Chassis
Dimensions
127 mm L x 76.2 mm W x 31.2 mm H
Open Frame/enclosed
Open Frame
Brand/series
BLP55 Series
Configuration
Open-Frame
Operation
Switching
Output
24 VDC @ 1.6 A
Power, Output
55 W
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
100 to 250 VAC
Voltage, Output
24 VDC
Output Current (max)
2.3A
Output Power (max)
40W
Screening Level
Commercial
Product Length (mm)
127mm
Product Height (mm)
28.7mm
Product Depth (mm)
76.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Pin Count
11
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2267
103354D Rev AB1, 06-FEB-09
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Ground Continuity
Dielectric Withstand Voltage
Electromagnetic Interference
ESD
Flicker
Radiated Susceptibility
EFT/Burst
Input Transient Protection
RF Immunity
Magnetic Fields
Leakage Current
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Forced-Air Cooling
Convection Cooling
Temperature Coefficient
Relative Humidity
Shock
Vibration
NOTES:
1
10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted
on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side.
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
0 °C to 70 °C with linear derating to 50% above 50 °C. Unit will start up at
-20 °C but will not meet all published specifications.
Forced-air cooling of 150 LFM at 10 CFM is required for full output power.
(See Model Selection Table).
When unit is mounted horizontally with free-air convection.
(See Model Selection Table).
0 °C to 70 °C (after 15-minute warm-up).
Non-Condensing.
Operating: half-sine 11 ±3ms, 3 axis.
Non-operating: half-sine 11±3ms, 3 axis.
Operating: Random vibration, 5-500 Hz (10 minutes each axis).
Non-operating: Random vibration, 5-500 Hz (10 minutes each axis).
CONDITIONS/DESCRIPTION
UL60950-1/CSA 22.2 No. 60950-1-03.
EN 60950-1/IEC 60950-1.
CB Approval.
CE Mark for LVD.
Input-to-Ground (Basic).
Input-to-Ouput (Reinforced). The primary to secondary test is not performed
Output-to-Ground (Functional).
FCC Part 15.
CISPR 22 and CISPR 11.
Per EN61000-4-2, level 3.
Per EN61000-3-3.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Per EN61000-4-6, level 3.
Per EN61000-4-8.
Per EN60950.
on completed assemblies.
BLP55-1XXX
BLP55-3XXX
Page 3 of 6
BLP55 AC-DC Series Data Sheet
Line-to-Ground:
Line-to-Line:
AT 264 VAC:
At 264 VAC:
Conducted:
Conducted:
1
1500
2121
3000
4242
500
MIN
MIN
-40
0
5
B
B
1
1
2
±0.02
NOM
NOM
25
3
3
1
www.power-one.com
0.48
0.72
MAX
MAX
10k
50k
2.4
6.0
70
85
40
95
15
40
55 Watts
40
ASL Ft.
ASL Ft.
UNITS
%/°C
%RH
Grms
Grms
UNITS
Class
VDC
VDC
VDC
VAC
VAC
V/m
V/m
A/m
mA
kV
kV
°C
°C
W
G
A

Related parts for BLP55-1024G