ZUP6-33/U TDK Corporation, ZUP6-33/U Datasheet - Page 24

PWR SUP BENCH PROG 0-6V 198W

ZUP6-33/U

Manufacturer Part Number
ZUP6-33/U
Description
PWR SUP BENCH PROG 0-6V 198W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP6-33/U

Voltage - Output
0 ~ 6V
Number Of Outputs
1
Power (watts)
198W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 6 VDC @ 33A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
198W
Operating Temperature
0°C ~ 50°C
Efficiency
72%
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Accuracy
0.02% + 5 mV
Brand/series
ZUP
Current, Output
33 A
Display Type
Digital Meter
Power, Output
198 W
Power, Rating
198 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
6 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1683
ZUP633/U
3.8.4 External Control Connector -
3.9 REPACKAGING FOR SHIPMENT
The external control connector is configured for Local sensing and no external On/Off control. Refer to
Fig: 3-6 below for the default configuration description. The default configuration is: Local sensing,
Rear panel On/Off disabled (On/Off can be controlled by the Front panel or by the serial communication
port), and output voltage and current are controlled by the Front panel or by the serial communication
port. For other configurations, remove the contact that should be modified, and replace it with a new
one with a suitable connection. Replacement contacts are supplied in the packaging of the power
supply.
To ensure safe transportation of the instrument, it is recommended to use the original package. The
original packaging material is reusable. If the original package is not available, contact the Nemic-
Lambda Sales or service facility near you for details on obtaining suitable packaging and shipping
information. Please attach a tag to the power supply describing the problem and specifying the owner,
model number and serial number of the power supply.
VCVP
VCCP
RCCP
COM
- S
+S
14
P
2
13
1
On/Off
Output Good
VRFV
VRFI
RCVP
- LS
+LS
Fig. 3-6:
External Control connector - default configuration
(ZUP rear panel view)
Default configuration connections

Related parts for ZUP6-33/U