HWS30-5/A TDK Corporation, HWS30-5/A Datasheet

PWR SUP IND 5V 6A SNG OUTPUT

HWS30-5/A

Manufacturer Part Number
HWS30-5/A
Description
PWR SUP IND 5V 6A SNG OUTPUT
Manufacturer
TDK Corporation
Series
HWSr
Type
Enclosedr
Datasheets

Specifications of HWS30-5/A

Number Of Outputs
1
Efficiency
80%
Voltage - Output
5V
Power (watts)
30W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 6A
Size / Dimension
3.74" L x 1.24" W x 3.23" H (95mm x 31.5mm x 82mm)
Power (watts) - Rated
30W
Operating Temperature
-10°C ~ 70°C
Approvals
CE, CSA, EN, IEC, UL
Output Current (max)
6A
Input Voltage
85 to 265V
Output Voltage
5V
Output Power (max)
30W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
5
Application
Process control, NC-machining, automotive, packaging equipment, materials handling, chemical processing, robots, burn-in and test, automated test, instrumentation, detection and measurement
Brand/series
HWS Series
Configuration
Enclosed
Current, Rating
6 A (Max.)
Load Regulation
40 mV
Operation
Switching
Output
5 VDC @ 6 A
Power, Output
30 W
Primary Type
AC-DC
Regulation, Line
20 mV
Special Features
PFC
Standards
Approved to UL, CSA Certified
Temperature Coefficient
0.02%⁄°C (Max.)
Temperature, Operating
-10 to +70 °C
Voltage, Input
85 to 265/120 to 370 VAC/VDC
Voltage, Output
5 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1340
HWS305/A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HWS30-5/A
Manufacturer:
TDK-LAMBDA
Quantity:
320
*10. Measured by the each measuring method of UL,CSA,EN and DENAN(at 60Hz).
*11. Ratings - Derating at standard mounting.
*12. As for DENAN, built to meet at 100VAC.
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
*3. Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
*4. Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz.
*5. 85 ~ 265VAC , constant load.
*6. No load-Full load, constant input voltage.
*7. Foldback current limit with automatic recovery. Not operate at over load or dead short condition for more than 30seconds.
*8. OVP circuit will shutdown output, manual reset (Re power on).
*9. At 100/200VAC , Ta=25°C, nominal output voltage and maximum output current.
*Read instruction manual carefully, before using the power supply unit.
10 Maximum Ripple & Noise
11 Maximum Line Regulation
12 Maximum Load Regulation
13 Temperature Coefficient
14 Over Current Protection
15 Over Voltage Protection
16 Hold-up Time (Typ)
17 Leakage Current
18 Remote Sensing
19 Parallel Operation
20 Series Operation
21 Operating Temperature
22 Operating Humidity
23 Storage Temperature
24 Storage Humidity
25 Cooling
26 Withstand Voltage
27 Isolation Resistance
28 Vibration
29 Shock (In package)
30 Safety
31 Line DIP
32 Conducted Emission
33 Radiated Emission
34 Immunity
35 Weight(Typ.)
36 Size (W x H x D)
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (Typ)
5 Input Voltage Range
6 Input Current (100/200VAC)(Typ) (*1)
7 Inrush Current(Typ)
8 PFHC
9 Output Voltage Range
ITEMS
to be described as 100 ~ 240VAC(50/60Hz).
For start up at low ambient temperature and low input voltage, output ripple noise might not meet specification.
However, there is no overshoot at start up and output ripple noise specification can be met after one second.
A225-01-01/A-B
=NOTES=
HWS30/A
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A225-01-02/A_).
(*1)
(*4)
MODEL
-10<Ta< 0°C
0<Ta<60°C
100VAC
200VAC
(*10) -
(*11) -
(*12) -
(*2) -
(*3) -
(*5) mV
(*6) mV
(*7) A
(*8) V
(*9) -
mm
mV
mV
W
%
%
V
A
A
V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SPECIFICATIONS
4.13~4.95
2.97~3.96
HWS30
0.6/0.3
Less than 0.5mA. 0.2mA(Typ) at 100VAC / 0.4mA(Typ) at 230VAC
-3/A
6.3 ~
120
160
3.3
20
70
73
20
40
6
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
More than 100M at 25°C and 70%RH Output - FG : 500VDC
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
-10 ~+60°C (-10 ~+40°C:100%,+50°C:60%,+60°C:20%)
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
6.25~7.25
HWS30
4.0~6.0
At no operating, 10 ~ 55Hz (Sweep for 1min)
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 370VDC
Built to meet SEMI-F47 (200VAC Line only)
31.5 x 82 x 95 ( Refer to Outline Drawing )
-5/A
6.3 ~
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
120
160
Output - FG : 500VAC (100mA) for 1min
30
77
80
20
40
6
5
19.6m/s
Built to meet UL508, DENAN
Built to meet IEC61000-3-2
30 ~ 90%RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
15.0~17.4
2
9.6~14.4
Less than 0.02% / °C
HWS30
Convection Cooling
Less than 196.1m/s
Constant, X,Y,Z 1hour each.
-12/A
2.62 ~
150
180
2.5
12
30
81
83
48
96
-30 ~ +85°C
Possible
20ms
260g
-
-
12.0~18.0
18.8~21.8
HWS30
0.8/0.4
-15/A
2.1 ~
150
180
120
15
30
81
83
60
2
2
DENSEI-LAMBDA
30.0~34.8
19.2~28.8
HWS30
-24/A
1.36 ~
31.2
200
240
192
1.3
24
83
86
96
38.4~52.8
55.2~64.8
HWS30
-48/A
0.68 ~
0.65
31.2
200
240
192
384
48
82
83

Related parts for HWS30-5/A

HWS30-5/A Summary of contents

Page 1

... Built to meet UL508, DENAN - Built to meet SEMI-F47 (200VAC Line only) - Built to meet EN55011/EN55022-B, FCC-B, VCCI-B - Built to meet EN55011/EN55022-B, FCC-B, VCCI-B - Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3), -5(Level 3,4), -6(Level 3), -8(Level 4 Refer to Outline Drawing ) DENSEI-LAMBDA HWS30 HWS30 HWS30 -12/A -15/A -24 2 ...

Page 2

... HWS30/A A225-01-02/A Ta(°C) -10 ~+ 120 100 - MOUNTING A MOUNTING B (STANDARD MOUNTING) OUTPUT DERATING LOAD(%) MOUNTING A,B,C,D 100 60 20 OUTPUT DERATING CURVE Ta(°C) MOUNTING C DENSEI-LAMBDA MOUNTING A,B,C MOUNTING D DON'T USE ...

Page 3

... Designed to meet SEMI-F47 (200VAC Line only Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B - Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3), - -5(Level 3,4), -6(Level 3), -8(Level 4), - Refer to Outline Drawing ) mm HWS30-9/A 9V 3.4A 30.6W 78% 81% 0.8A/0.4A 7.2V-10.8V 150mV 180mV 36mV 72mV Less than 0.02% / °C 3.57A < ...

Related keywords