LS100-5 TDK Corporation, LS100-5 Datasheet - Page 12

POWER SUPPLY 5V 16A SGL OUTPUT

LS100-5

Manufacturer Part Number
LS100-5
Description
POWER SUPPLY 5V 16A SGL OUTPUT
Manufacturer
TDK Corporation
Series
LSr
Type
Industrialr
Datasheets

Specifications of LS100-5

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 16A
Size / Dimension
6.3" L x 3.8" W x 1.5" H (160mm x 96.5mm x 38.1mm)
Power (watts) - Rated
80W
Operating Temperature
-25°C ~ 70°C
Efficiency
79%
Approvals
CE, EN, IEC, UL
Brand/series
LS Series
Configuration
Enclosed
Current, Output
16.0
Frequency, Input
47-63 Hz
Height
1.5 Inch
Length
6.3 Inch
Line Regulation
20 mV
Load Regulation
40 mV
Operation
Switching
Output
5 VDC @ 16 A
Power Rating
80 Watts
Power, Output
80 W
Primary Type
AC-DC
Ripple, Rejection
80 mV
Temperature, Operating
–25 to 70 degree C
Temperature, Storage
–40 to 85 degree C
Voltage, Adjustment Range
4.75-5.50
Voltage, Input
88 to 264/125 to 373 VAC/VDC
Voltage, Output
5 VDC
Weight
21.5 Ozs.
Width
3.8 Inch
Output Current (max)
16A
Output Voltage
5V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
38.1mm
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1810
LS1005

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LS100-5
Manufacturer:
TDK-LAMBD
Quantity:
617
5-2 Mounting Method
1)
2)
3)
6. Wiring Method
This is convection cooling type power supply. In consideration of the heat radiation and safety, please keep a dis-
tance of more than 15mm between the power supply and the peripheral parts. When lining up multiple units, please
make sure to place them 15mm or more apart from each other.
Maximum allowable penetration of mounting screws into the power-supply is 5mm except LS25 (4mm).
Recommended torque for mounting screws of LS25 ~ LS150 (M3 screw) : 0.49 N⋅m (5.0 kgf⋅cm).
The input and output load wires shall be separated and twisted to improve noise immunity.
Both wires must be as thick and short as possible to make lower impedance.
Noise can be reduced by connecting a film capacitor with 0.1uF capacitance across the load terminals.
For safety and EMI considerations, connect the FG terminal of LS series to mounting set ground terminal.
The recommended wire type :
Note 1 : When using separate loads, it is recommended to use 2 pieces of 0.8mm thick crimp-type terminal.
Note 2 : For recommended wire diameter, refer to wire maker recommended allowable current and voltage
MODEL
LS35 ~ LS150
LS25
drop. For higher output current model like 3.3V & 5V, bigger diameter wire is recommended.
Recommended
AWG16-22
AWG14-22
Wire
M3.0 Screws
0.49 N⋅m (5.0 kgf⋅cm)
M3.5 Screws
1.0 N⋅m (9.8 kgf⋅cm) ~
1.4 N⋅m (13.7 kgf⋅cm)
Recommended torque
11
Recommended crimp-type terminal
(MAX)
6.0mm
6.8mm
D
LS
INSTRUCTION MANUAL
TDK-Lambda
25-150
0.8mm
0.8mm
(MAX)
t
Series
Mounting
2 pieces
2 pieces
(MAX)
Pieces

Related parts for LS100-5