LS100-36 TDK Corporation, LS100-36 Datasheet

POWER SUPPLY 36V 3A SGL OUTPUT

LS100-36

Manufacturer Part Number
LS100-36
Description
POWER SUPPLY 36V 3A SGL OUTPUT
Manufacturer
TDK Corporation
Series
LSr
Type
Industrialr
Datasheets

Specifications of LS100-36

Number Of Outputs
1
Efficiency
86%
Voltage - Output
36V
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
36 VDC @ 3A
Size / Dimension
6.3" L x 3.8" W x 1.5" H (160mm x 96.5mm x 38.1mm)
Power (watts) - Rated
108W
Operating Temperature
-25°C ~ 70°C
Approvals
CE, EN, IEC, UL
Output Current (max)
3A
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
38.1mm
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
5
Brand/series
LS Series
Configuration
Enclosed
Current, Output
3.0
Frequency, Input
47-63 Hz
Height
1.5 Inch
Length
6.3 Inch
Line Regulation
144 mV
Load Regulation
288 mV
Operation
Switching
Output
36 VDC @ 3 A
Power Rating
108 Watts
Power, Output
108 W
Primary Type
AC-DC
Ripple, Rejection
150 mV
Temperature, Operating
–25 to 70 degree C
Temperature, Storage
–40 to 85 degree C
Voltage, Adjustment Range
32.00-40.00
Voltage, Input
88 to 264/125 to 373 VAC/VDC
Voltage, Output
36 VDC
Weight
21.5 Ozs.
Width
3.8 Inch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1808
LS10036

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LS100-36
Manufacturer:
TDK-LAMBDA
Quantity:
617
(1)
(2)
S p e c i f i c a t i o n s
ITEMS
AC Input Voltage (300VAC for 5s)
Input Frequency
DC Input Voltage
Inrush Current (230VAC, cold start)
Power Factor
Input Current (115/230VAC)
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (115 / 230V input)
Leakage Current (230VAC 60Hz)
Remote Sense
LED Indicator
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Immunity
Safety Agency Approvals
Conducted & Radiated EMI
MTBF (MIL-HDBK-217F)
Weight (Typ)
Size (LxWxH)
Warranty
Switch selectable for 115 or 230VAC
LS25-3
LS50, LS75-3 & -5
LS75-12, -15, -24, -36, -48
LS100-3 & -5
LS100-12, -15, -24, -36, -48
LS150-3 & -5,
LS150-12, -15, -24, -36, -48
Derate linearly to 60% load from +40 to +70°C.
Derate linearly to 70% load from +50 to +70°C.
Derate linearly to 60% load from +50 to +70°C.
Derate linearly to 60% load from +45 to +70°C. Derate linearly to 80% load from 115V to 88VAC input.
Derate linearly to 60% load from +50 to +70°C. Derate linearly to 80% load from 115V to 88VAC input.
Derate linearly to 50% load from +40 to +70°C.
Derate linearly to 70% load from +50 to +70°C.
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
VDC
VAC
mA
hrs
ms
yrs
Hz
in
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.1 x 2.0 x 1.1
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
0.7 / 0.4
906,997
14 / 80
LS25
170
30
Single Output General Purpose Power Supplies
3.3V: 3.8-4.45V, 5V: 5.75-6.75V, 12V: 13.8-16.2V, 15V: 17.25-20.25V,
-25 to +70°C. Derate linearly to 50% load from +50 to +70°C (2)
10 - 55Hz: 19.6m/s
3.9 x 3.2 x 1.4
0.8 / 0.55
706,464
>100M at 25C & 70%RH, Output to Ground 500VDC
12 / 80
24V: 27.6-32.4V, 36V: 41.4-48.6V, 48V: 55.2-64.8V
LS35
270
40
UL60950-1, EN60950-1, IEC60950-1, CE Mark
88 - 264VAC (See note (2) for LS100)
Test & Measurement
Automated Service
IEC61000-4-2, -3, -4, -5, -6, -8, -11
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Very low cost
Small size
115VAC or 230VAC input
Withstands 300VAC surges (5s)
Three year warranty
20 - 90% RH (non condensing)
10 - 95% RH (non condensing)
EN55011/EN55022-B, FCC-B
125 - 373VDC
3.9 x 3.8 x 1.4 5.1 x 3.8 x 1.5
Meets EN61000-3-2, -3
1.3 / 0.8
712,890
14 / 60
2
< 196.1 m/s
LS50
350
LS Series
constant sweep 1 min X, Y, Z for 1 hour
40
Green LED = On
-40 to +85°C
<0.02%/°C
Three Years
Convection
47 - 63Hz
> 110%
<1mA
No
2
1.6 / 1.0
648,786
14 / 60
(20G)
LS75
410
40
6.3 x 3.8 x 1.5
2.2 / 1.2
25 / 150
545,375
LS100
600
60
88-132/176-264VAC(1)
248 - 273VDC
7.8 x 3.9 x 1.5
505,393
20 / 28
3.5 / 2
LS150
700
40
59

Related parts for LS100-36

LS100-36 Summary of contents

Page 1

... Small size 115VAC or 230VAC input Withstands 300VAC surges (5s) Three year warranty & Test & Measurement Automated Service LS25 LS35 LS50 88 - 264VAC (See note (2) for LS100) 125 - 373VDC Meets EN61000-3-2, -3 0.7 / 0.4 0.8 / 0.55 1.3 / 0.8 3.3V: 3.8-4.45V, 5V: 5.75-6.75V, 12V: 13.8-16.2V, 15V: 17.25-20.25V, 24V: 27 ...

Page 2

... LS75-48 48V LS100-3.3 3.3V 3.0 - 3.6 LS100-5 5V 4.75 - 5.5 LS100-12 12V 10.8 - 13.2 LS100-15 15V 13.5 - 16.5 LS100-24 24V 22 - 27.2 LS100-36 36V LS100-48 48V LS150-3.3 3.3V 3.0 - 3.6 LS150-5 5V 4.75 - 5.5 LS150-12 12V 10.8 - 13.2 LS150-15 15V 13.5 - 16.5 LS150-24 24V ...

Related keywords