LPQ253-CEF Emerson Network Power, LPQ253-CEF Datasheet

PWR SUPP 250W 5/15/15/5-25V EFC

LPQ253-CEF

Manufacturer Part Number
LPQ253-CEF
Description
PWR SUPP 250W 5/15/15/5-25V EFC
Manufacturer
Emerson Network Power
Series
LPQ250r
Datasheets

Specifications of LPQ253-CEF

Voltage - Output
5V, ±15V, 25V
Number Of Outputs
4
Power (watts)
250W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 35A
2nd Output
15 VDC @ 10A
3rd Output
-15 VDC @ 6A
4th Output
25 VDC @ 6A
Size / Dimension
10.32" L x 5" W x 2" H (262mm x 127mm x 50.8mm)
Power (watts) - Rated
250W
Operating Temperature
0°C ~ 50°C
Efficiency
75%
Approvals
CB, CE, CSA, NEMKO, UL, VDE
Line Regulation
±2%, ±3%
Load Regulation
±2%, ±3%
Power Supply Output Type
Fixed & Variable
No. Of Output Channels
4
Input Frequency
440Hz
Output Voltage
5V
Output Current
35A
Power Rating
250W
Input Voltage
85VAC
No. Of Outputs
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
454-1218
LPQ253-CEF
124
250 Watts
LPQ250 Series
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major
resonances 0.7 G peak 5 Hz to 500 Hz,
operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full
load and 25°C ambient conditions
• Active power factor correction
• IEC EN61000-3-2 compliance
• Remote sense on main output
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Adjustable floating 4th output
• 2 Supervisory outputs 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Cover -C
• 120 KHz switching frequency
• Optional with fan cover -CF
• Optional end fan cover -CEF
Americas: (760) 930-4600
Environmental
Special Features
Technical Support: (888) 41-ASTEC or (407) 241-2752
Europe (UK) 44 (1384) 842-211
Total Power:
Input Voltage: 85-264 VAC
# of Outputs:
VDE
UL
CSA
NEMKO EN 60950/EMKO-TUE
CB
CE
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Power factor
Safety ground leakage
current
Output
Maximum power
Adjustment range
Supervisory outputs
Hold-up time
Overload protection
Overvoltage protection
Logic Control
Power failure
Remote on/off
DC-OK
Remote sense
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 5
(74-sec) 203
Certificate and report
Mark (LVD)
250 Watts
120-300 VDC
Quad
Electrical Specs
Asia (HK) 852-2437-9662
Safety
85-264 VAC; 120-300 VDC
47-440 Hz
20 A max., cold start @ 25°C
75% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and
radiated
VDE 0878 PT3 Class B conducted and
radiated.
0.99 typical
<0.5 mA @ 50/60 Hz, 264 VAC input
With cover: 250 W with 30 CFM forced
air,
(-C) (-CF) (-CEF).
±5% min. on main: 5-25 V on 4th output
5 V @ 100 mA regulated, 12 V @ 500
mA
16 ms @ 250 W load, 115 VAC nominal
line
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5 V output: 5.7-6.7 VDC.
TTL logic signal goes high 50-150 msec
after 5V output. It goes low at least 4
msec before loss of regulation
Requires an external contact (N.O or
N.C) to inhibit outputs
TTL logic goes high 50-150 msec after 5
V output. It goes low when there is loss
of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
11774-3336-1262
E132002
LR53982C
P95103550
2186
rev 12.14.03

Related parts for LPQ253-CEF

LPQ253-CEF Summary of contents

Page 1

Watts LPQ250 Series Special Features • Active power factor correction • IEC EN61000-3-2 compliance • Remote sense on main output • Power fail and remote inhibit • Single wire current sharing • Built-in EMI filter • Adjustable floating 4th ...

Page 2

... Voltage Load LPQ252 + - ±5- LPQ253 + - ±5- Peak current lasting <30 seconds with a maximum 10% duty cycle 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. ...

Related keywords