MAP40-1005 POWER ONE, MAP40-1005 Datasheet - Page 3

PWR SUP 40W 5V 8A OUTPUT CHASSIS

MAP40-1005

Manufacturer Part Number
MAP40-1005
Description
PWR SUP 40W 5V 8A OUTPUT CHASSIS
Manufacturer
POWER ONE
Series
MAP40r
Type
Open Framer
Datasheets

Specifications of MAP40-1005

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 8A
Size / Dimension
6" L x 3.27" W x 1.6" H (152.4mm x 83.1mm x 40.6mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
73%
Approvals
CE, CSA, EN, UL
Line Regulation
0.2%
Load Regulation
±1.5%
Output Current (max)
8A
Input Voltage
90 to 132/175 to 264V
Output Voltage
5V
Output Power (max)
55W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
83.1mm
Product Height (mm)
40.6mm
Product Depth (mm)
152.4mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
11
Product
Switching
Brand/series
MAP40 Series
Configuration
Open-Frame
Current, Input
1.2 A (RMS) (Max.)
Current, Output
8 A (Max.)
Dimensions
5.00 in. L x 3.00 in. W x 0.25 in. H
Frequency, Operating
47 to 63 Hz
Operation
Switching
Output
5 VDC @ 8 A
Power, Output
40 W
Power, Rating
40 W
Primary Type
AC-DC
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
0 to 50 °C
Voltage, Input
110/220 VAC
Voltage, Output
5 VDC
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2020
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
REV. JUN 19, 2006 revised to APR 13, 2007
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
CONDITIONS/DESCRIPTION
Operating.
Non-operating.
Derate linearly above 50°C by 2.5%
per °C to a maximum temperature of 70°C.
0°C to 70°C (after 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
Page 3 of 5
MAP30/40/42 AC-DC Series Data Sheet
At 100% load:
At 50% load:
MIN
-40
0
0
5
±0.02
NOM
www.power-one.com
±0.03
MAX
10k
40k
50
70
85
95
20
6
ASL Ft.
ASL Ft.
UNITS
%/°C
%RH
G
°C
°C
°C
RMS
G

Related parts for MAP40-1005