MAP40-3000 POWER ONE, MAP40-3000 Datasheet - Page 2

PWR SUPPLY 40W +5V,+12V,-12V,OUT

MAP40-3000

Manufacturer Part Number
MAP40-3000
Description
PWR SUPPLY 40W +5V,+12V,-12V,OUT
Manufacturer
POWER ONE
Series
MAP40r
Type
Open Framer
Datasheets

Specifications of MAP40-3000

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
2nd Output
12 VDC @ 2A
3rd Output
-12 VDC @ 300mA
Size / Dimension
5" L x 3" W x 1.16" H (127mm x 76.2mm x 29.5mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CE, CSA, EN, UL
Line Regulation
0.2%, 1%
Load Regulation
2%, 3.5%
Output Current (max)
3/2/0.3A
Input Voltage
85 to 264V
Output Voltage
5/12/-12V
Output Power (max)
40W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
76.2mm
Product Height (mm)
29.5mm
Product Depth (mm)
127mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Screw
Pin Count
8
Product
Switching
Brand/series
MAP40 Series
Configuration
Open-Frame
Current, Input
1.2 A (RMS) @ 90 VAC
Current, Inrush
38 A (Max.) (Surge)
Hold Time
15 ms (Min.) @ 90 VAC
Operation
Switching
Output
-12 VDC @ 0.3 A, +5 VDC @ 3 A, +12 VDC @ 2 A
Power, Output
40 W
Power, Rating
40 W
Primary Type
AC-DC
Standards
UL Listed, CSA Certified, TUV Approved
Temperature Coefficient
±0.02%⁄°C (Nom.)
Temperature, Operating
0 °C
Voltage, Input
90 to 264 VAC
Voltage, Output
-12, +5, +12 VDC
Voltage, Output 1
5 V
Voltage, Output 2
12 V
Voltage, Output 3
-12 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2095
PW9903
REV. JUN 19, 2006 revised to APR 13, 2007
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Interface Signals and Internal Protection
PARAMETER
Overvoltage
Protection
Overload
Protection
Remote Sense
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference
Input Transient
Protection
Insulation Resistance
Leakage Current
NOTES:
1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A.
2) MAP40-3000, MAP40-3003, MAP3500 meet Class A.
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (40W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Switching frequency of power supply (fixed frequency).
CONDITIONS/DESCRIPTION
Full load, 120VAC.
Single output models; MAP30, MAP42.
All multiple output models, see regulation graphs.
Full load, 20 MHz bandwidth.
Multiple output models with convection cooling.
Output voltage overshoot/undershoot at turn-on, V1.
Varies by output, total regulation includes: Line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only of multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Total cable drop, single output models only.
CONDITIONS/DESCRIPTION
UL60950.
CSA 22.2 No. 60950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 part 15 sub-part B - conducted.
EN55022 / CISPR 22 conducted (Note 1).
EN55022 / CISPR 22 radiated (Note 2).
EN61000-4-5 Level 3
Input to output.
Per EN60950, 264VAC
MAP30-1005, MAP40-3000, MAP40-3003
Main output only of multiple output units.
MAP42, MAP40-3100, 3001, 3105, 3500
Page 2 of 5
MAP30/40/42 AC-DC Series Data Sheet
MAP30-1005, MAP42-1005
MAP30, MAP40
Line to Ground
MAP42-1012
MAP42-1024
Line to Line
MAP42
2600
20.0
32.0
MIN
MIN
MIN
MIN
0.0
5.8
5.8
85
90
47
85
15
23
1
2
7
NOM
NOM
NOM
NOM
500
130
25
70
See Model Selection Chart.
See regulation graphs.
20
1
B
B
B
www.power-one.com
Approved.
22.0
37.0
MAX
264
264
MAX
MAX
250
MAX
500
750
1.2
6.8
6.8
63
38
30
40
1
2
Amps
Watts
UNITS
A
UNITS
UNITS
UNITS
Class
VDC
VAC
VAC
A
kHz
Sec
mV
ms
ms
μA
Hz
μs
kV
RMS
%
%
%
V
PK