LS100-24 TDK Corporation, LS100-24 Datasheet
LS100-24
Specifications of LS100-24
LS10024
Available stocks
Related parts for LS100-24
LS100-24 Summary of contents
Page 1
LS25~150 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. WARNING and CAUTION ...
Page 2
... The output load line and input line shall be separated and twisted to improve noise immunity. LS25, LS35, LS50, LS75 - LOAD + Maximum output current of each output terminal is 25A except for LS25 (15A). If more than 25A, use 2 terminals. TDK-Lambda LS 25-150 INSTRUCTION MANUAL LS100, LS150 - LOAD + 1 Series ...
Page 3
... Explanation of Functions and Precautions 3-1. Input Voltage Range Input voltage range is single phase 88 ~ 264VAC (47 ~ 63Hz) or 125 ~ 373VDC for LS25 ~ LS100. For LS150, selectable switch 115/230VAC will decide the input voltage range as mentioned in the table below. Input voltage which is out of specification, may damage the unit. For cases where conformance to various safety specs(UL,CSA,EN) are required, input voltage range will be 100~240VAC (50/60Hz ) ...
Page 4
Series Operation For series operation, either method ( possible. Method ( A ) Power Supply Output Terminal Output Terminal Note : In case of Method ( A ), please connect diodes to ...
Page 5
Isolation / Withstand Voltage 4-1. Isolation Test Isolation resistance between output and FG (chassis) shall be more than 100MΩ at 500VDC. For safety, voltage setting of DC isolation tester must be done before the test. Ensure that the unit ...
Page 6
Mounting Directions 5-1. Output Derating according to the Mounting Directions Recommended standard mounting is Method ( A ). Method ( and ( D ) are also possible. Refer to the Output Derating below. Please ...
Page 7
LS25-5, -12, -15, -24, -36 & -48 Output Derating Vs Ambient Temperature Load (%) 120 100 -25 0 LS35-3.3, -5, -12, -15, -24, -36 & -48 Output Derating Vs Ambient Temperature Load (%) 120 ...
Page 8
LS50-3.3, -5, -12, -15, -24, -36 & -48 Load (%) Output Derating Vs Ambient Temperature 120 100 -25 0 LS75-3.3, -5 Load (%) Output Derating Vs Ambient Temperature 120 100 ...
Page 9
... LS75-12, -15, -24, -36 & -48 Load (%) Output Derating Vs Ambient Temperature 120 100 -25 0 LS100-3.3, -5 Output Derating Vs Ambient Temperature Load (%) 120 100 - Ambient Temperature (° Ambient Temperature (°C) 8 TDK-Lambda LS Series 25-150 INSTRUCTION MANUAL Mounting A, B & D Mounting C 100 75 Mounting A & B Mounting C & D 100 ...
Page 10
... LS100-12, -15, -24, -36 & -48 Output Derating Vs Ambient Temperature Load (%) 120 100 -25 0 LS150-3.3, -5 Load (%) Output Derating Vs Ambient Temperature 120 100 - Ambient Temperature (° Ambient Temperature (°C) 9 TDK-Lambda LS Series 25-150 INSTRUCTION MANUAL Mounting A & B Mounting C & D 100 75 Mounting A Mounting B, C & D 100 ...
Page 11
... LS150-12, -15, -24, -36 & -48 Load (%) Output Derating Vs Ambient Temperature 120 100 -25 0 (B) Output Derating versus Input Voltage (Convection Cooling) LS100-3.3, -5, -12, -15, -24, -36 & -48 Output Derating Vs Input Voltage LOAD (%) 120 100 115 88 NOTE : LS25, LS35, LS50, LS75 & LS150 series do not require Input Voltage Derating. 40 ...
Page 12
Mounting Method 1) This is convection cooling type power supply. In consideration of the heat radiation and safety, please keep a dis- tance of more than 15mm between the power supply and the peripheral parts. When lining up multiple ...
Page 13
... LS25 : F1.6A , 250V LS35, LS50 : T2A , 250V LS75 : T2.5A , 250V LS100 : F4A , 250V LS150 : F5A , 250V 8. Before concluding that the unit is at fault, make the following checks. Check if the rated input voltage is connected. Check if the wiring of input and output is correct. Check if the wire size is correct. ...