PTV12010LAD Emerson Network Power, PTV12010LAD Datasheet - Page 3

CONV DC/DC 12 VIN ADJOUT 8A

PTV12010LAD

Manufacturer Part Number
PTV12010LAD
Description
CONV DC/DC 12 VIN ADJOUT 8A
Manufacturer
Emerson Network Power
Series
PTV12010r
Type
Point of Load (POL) Non-Isolated with Remote On/Off and UVLOr
Datasheet

Specifications of PTV12010LAD

Output
0.8 ~ 1.8V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Through Hole
Voltage - Input
10.8 ~ 13.2V
Package / Case
8-SIP Module
1st Output
0.8 ~ 1.8 VDC @ 8A
Size / Dimension
0.90" L x 0.33" W x 0.40" H (22.86mm x 8.38mm x 10.16mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 85°C
Efficiency
87%
Approvals
CAN/CSA, cUL, TUV, UL
Output Power
15 W
Input Voltage Range
10.8 V to 13.2 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.8 V to 1.8 V
Output Current (channel 1)
8 A
Package / Case Size
22.86 mm x 10.16 mm x 8.38 mm
Output Voltage
0.8 V to 1.8 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1333
PTV12010W Characteristic Data
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS
Inhibit
Track
GND
Vin
90
80
70
60
50
40
30
20
90
80
70
60
50
40
30
20
0
0
Vin = 12 V, Output Voltage = 1.8 V (See Note A)
(Required)
Vin = 12 V, Output Voltage = 5 V (See Note A)
100uF
C1
1
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
(Required)
Figure 5 - Standard Application
Figure 1 - Safe Operating Area
Figure 3 - Safe Operating Area
Ceramic
2
2
10uF
C2
8
3
7
Inhibit
Vin
POLA Non-isolated
4
4
Track
6
PTVxx010
5
GND
1 2 V i n s i n g l e o u t p u t
5
1
PTV12010
Vo Adj
6
6
Vo
4
0.05W
Rset
1%
2
3
7
8
8
Optional
100uF
C3
400 LFM
200 LFM
100 LFM
Nat conv
400 LFM
200 LFM
100 LFM
Nat conv
GND
Vo
O
A
D
L
N N o o t t e e s s
A
B
SOA curves represent the conditions at which internal components are
within the Artesyn derating guidelines.
Characteristic data has been developed from actual products tested at
25 °C. This data is considered typical data for the converter.
100
90
80
70
60
50
90
80
70
60
50
40
30
20
0
0
Vin = 12 V, Output Voltage = 3.3 V (See Note A)
1
Figure 4 - Efficiency vs Load Current
OUTPUT CURRENT (A)
Figure 2 - Safe Operating Area
2
2
OUTPUT CURRENT (A)
Vin = 12 V (See Note B)
3
4
File Name: ptv12010w.pdf Rev (02): 19 Dec 2005
4
5
6
NEW Product
6
7
8
8
400 LFM
200 LFM
100 LFM
Nat conv
Vout
5.0V
3.3V
1.8V
1.2V
3