QRW010A0B71-H Lineage Power, QRW010A0B71-H Datasheet - Page 31

CONVERTER DC/DC 12V 120W OUT T/H

QRW010A0B71-H

Manufacturer Part Number
QRW010A0B71-H
Description
CONVERTER DC/DC 12V 120W OUT T/H
Manufacturer
Lineage Power
Series
QRWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of QRW010A0B71-H

Output
12V
Number Of Outputs
1
Power (watts)
120W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
10-DIP Module
1st Output
12 VDC @ 10A
Size / Dimension
2.28" L x 1.45" W x 0.38" H (57.9mm x 36.8mm x 9.7mm)
Power (watts) - Rated
120W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Data Sheet
June 2, 2009
Thermal Considerations
The power modules operate in a variety of thermal environ-
ments; however, sufficient cooling should be provided to help
ensure reliable operation of the unit. Heat-dissipating compo-
nents are mounted on the top side of the module. Heat is
removed by conduction, convection and radiation to the sur-
rounding environment. Proper cooling can be verified by
measuring the temperature of selected components on the
topside of the power module (See 56). Peak temperature
(Tref) can occur at any of these positions indicated in Figure
50.
Note:Top view, pin locations are for reference only.
Figure 56. Temperature Measurement Location.
The temperature at any one of these locations should not
exceed per 1 to ensure reliable operation of the power mod-
ule. The output power of the module should not exceed the
rated power for the module as listed in the Ordering Informa-
tion table.
Although the maximum Tref temperature of the power mod-
ules is per 1, you can limit these temperatures to a lower
value for extremely high reliability.
Table 1.
Lineage Power
Thermocouple
Location T
Output Voltage
1.0V
1.2V
1.5V
1.8V
2.5V
3.3V
12V
5V
Device Temperature
ref
1
Airflow
Device
Tref1
Tref1
Tref1
Tref1
Tref1
Tref1
Tref2
Tref3
Tref1
Tref1
Thermocouple
Location T
QRW010/025/035/040 Series Power Modules; dc-dc Converters
ref
3
Thermocouple
Location T
Temperature (°C)
36 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
116
119
118
117
118
114
112
130
113
118
ref
2
Heat Transfer Without Heat Sinks
Increasing airflow over the module enhances the heat trans-
fer via convection. Figures 57 through 64 shows the maxi-
mum current that can be delivered by the corresponding
module without exceeding the maximum case temperature
versus local ambient temperature (TA) for natural convection
through 2 m/s (400 ft./min.).
Note that the natural convection condition was measured at
0.05 m/s to 0.1 m/s (10ft./min. to 20 ft./min.); however, sys-
tems in which these power modules may be used typically
generate natural convection airflow rates of 0.3 m/s (60 ft./
min.) due to other heat dissipating components in the system.
The use of output power derating curve is shown in the fol-
lowing example.
What is the minimum airflow necessary for a QRW035A0F
operating at VI = 48 V, an output current of 23A, and a maxi-
mum ambient temperature of 70 °C.
Solution
Given: VI = 48V
Io = 23A
TA = 70 °C
Determine airflow (v) (Use Figure 62):
v = 1m/sec. (200ft./min.)
Figure 57. Output Power Derating for QRW040A0S1R0
Figure 58. Output Power Derating for QRW040A0P (Vo =
40
35
30
25
20
15
10
5
0
20
(Vo = 1.0V) in Transverse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
LOCAL AMBIENT TEMPERATURE, T (°C)
1.2V) in Transverse Orientation with No
Baseplate; Airflow direction from VIN (+) to
VIN (–); VIN = 48V.
30
LOCAL AMBIENT TEMPERATURE, T (°C)
40
50
60
70
A
A
80
90
31

Related parts for QRW010A0B71-H