QRW010A0B71-H Lineage Power, QRW010A0B71-H Datasheet - Page 2

CONVERTER DC/DC 12V 120W OUT T/H

QRW010A0B71-H

Manufacturer Part Number
QRW010A0B71-H
Description
CONVERTER DC/DC 12V 120W OUT T/H
Manufacturer
Lineage Power
Series
QRWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of QRW010A0B71-H

Output
12V
Number Of Outputs
1
Power (watts)
120W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
10-DIP Module
1st Output
12 VDC @ 10A
Size / Dimension
2.28" L x 1.45" W x 0.38" H (57.9mm x 36.8mm x 9.7mm)
Power (watts) - Rated
120W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lineage Power
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated
part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a
maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s
data for further information.
Data Sheet
June 2, 2009
Input Voltage:Continuous
Operating Ambient Temperature
(See Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage (100% factory Hi-Pot tested)
When using optional case ground pin
(option 7)
Operating Input Voltage
Maximum Input Current
(VI = 0 V to 75 V; IO = IO, max)
Inrush Transient
Input Reflected Ripple Current, peak-peak
(5 Hz to 20 MHz, 12 µH source impedance
See Test configuration section)
Input Ripple Rejection (120 Hz)
Transient (100ms)
Parameter
Parameter
QRW010/025/035/040 Series Power Modules; dc-dc Converters
36 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
Device
Device
All
All
All
All
All
All
All
All
Symbol
VIN
VI, trans
I
Symbol
2
t
Tstg
TA
VI
Min
36
1500
Min
–40
–55
700
Typ
48
16
60
Max
100
125
Vdc
Vdc
80
85
Max
4.5
75
1
mAp-p
Unit
Unit
Vdc
Vdc
Vdc
Adc
A
dB
°C
°C
2
s
2

Related parts for QRW010A0B71-H