QHW075F1-Q Lineage Power, QHW075F1-Q Datasheet - Page 2

no-image

QHW075F1-Q

Manufacturer Part Number
QHW075F1-Q
Description
CONVRTR DC/DC 3.3V 49.5W OUT
Manufacturer
Lineage Power
Series
QHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of QHW075F1-Q

Output
3.3V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
8-DIP Module
1st Output
3.3 VDC @ 15A
Size / Dimension
2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
81%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
QHW075F1-Q
Manufacturer:
TYCO
Quantity:
387
QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules;
dc-dc Converters: 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow fuse with a maximum rating of 20 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Input Voltage:
Operating Case Temperature
Storage Temperature
I/O Isolation Voltage (for 1 minute)
Operating Input Voltage
Maximum Input Current:
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
Input Ripple Rejection (120 Hz)
(See Thermal Considerations section.)
(5 Hz to 20 MHz, 12 µH source impedance;
see Figure 17.)
Continuous
Transient (100 ms)
V
V
I
I
QHW050F1-Q
QHW075F1-Q
QHW100F1-Q
QHW050F1-Q
QHW050F1-Q
QHW075F1-Q
= 0 V to 75 V; I
= 36 V to 75 V; I
Parameter
Parameter
O
O
= I
= I
O, max
O, max
; see Figures 1—3:
:
Symbol
V
Symbol
I, trans
T
T
V
stg
I
I
I
I
I
I
C
I, max
I, max
I, max
I, max
I, max
I, max
I
V
i
2
I
I
t
I
Min
36
Min
–40
–55
Typ
48
10
60
1500
Max
100
100
125
75
Max
2.5
3.5
4.5
1.9
2.7
3.5
1.0
75
Lineage Power
Data Sheet
April 2008
Unit
Vdc
Vdc
°C
°C
mAp-p
V
Unit
Vdc
A
dB
A
A
A
A
A
A
2
s

Related parts for QHW075F1-Q