Page 1
... Description The QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from typical full-load efficiency of 85% ...
Page 2
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso- lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet ...
Page 3
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Electrical Specifications Table 2. Output Specifications Parameter Output Voltage Set Point ( ° max C Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life ...
Page 4
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output General Specifications Parameter Calculated MTBF ( max Weight Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See the Feature Descriptions section for additional information. ...
Page 5
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Characteristic Curves The following figures provide typical characteristics for the power modules. 1.4 1.2 1 0.8 0.6 0.4 0 INPUT VOLTAGE, V Figure 1. Typical QHW050F1-Q Input Characteristics at Room Temperature 2 ...
Page 6
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Characteristic Curves (continued 1.5 3 4.5 6 7.5 9 OUTPUT CURRENT, I Figure 5. Typical QHW075F1-Q Converter Efficiency vs. Output Current at Room Temperature OUTPUT CURRENT, I Figure 6. Typical QHW100F1-Q Converter Efficiency vs. Output Current at Room Temperature 6 10 ...
Page 7
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Characteristic Curves (continued TIME μs/div) Note: See Figure 18 for test conditions. Figure 9. Typical QHW100F1-Q Output Ripple Voltage at Room Temperature; I TIME, t (100 μs/div) Note: Tested with a 1000 µF aluminum and a 1.0 µF ceramic capaci- tor across the load ...
Page 8
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Characteristic Curves (continued) TIME, t (50 μs/div) Note: Tested with a 1000 µF aluminum and a 1.0 µF ceramic capaci- tor across the load. Figure 13. Typical QHW050F1-Q Transient Response to Step Decrease in Load from 50% to 25% of Full Load at Room Temperature and 48 Vdc Input ...
Page 9
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Test Configurations TO OSCILLOSCOPE L TEST 12 μH 220 μ ESR < 0.1 Ω °C, 100 kHz BATTERY ESR < 0.7 Ω Note: Measure input reflected-ripple current with a simulated source inductance ( µ ...
Page 10
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Feature Descriptions Overcurrent Protection To provide protection in a fault (output overload) condi- tion, the unit is equipped with internal current-limiting circuitry and can endure current limiting for up to one second. If overcurrent exists for more than one second, the unit will shut down ...
Page 11
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Feature Descriptions (continued) Remote Sense (continued) SENSE(+) SENSE(–) V (+) V (+) I O SUPPLY (–) V (– CONTACT RESISTANCE Figure 21. Effective Circuit Configuration for Single-Module Remote-Sense Operation ...
Page 12
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Feature Descriptions (continued) Output Overvoltage Protection The output overvoltage protection consists of circuitry that monitors the voltage on the output terminals. If the voltage on the output terminals exceeds the overvolt- age protection threshold, then the module will shut down and latch off ...
Page 13
... A 8-2321(F). 3.0 m/s (600 ft./min.) 2.0 m/s (400 ft./min.) 5 1.0 m/s (200 ft./min.) 0.1 m/s (20 ft./min.) 4 NATURAL 3 CONVECTION 100 Figure 28. QHW075F1-Q Power Dissipation vs. (°C) A 8-2318(F). OUTPUT CURRENT, I (A) O Output Current at 25 ° 1.5 3 4.5 6 7.5 9 10.5 12 OUTPUT CURRENT, I ...
Page 14
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Thermal Considerations Heat Transfer Without Heat Sinks OUTPUT CURRENT, I Figure 29. QHW100F1-Q Power Dissipation vs. Output Current at 25 °C Heat Transfer with Heat Sinks The power modules have through-threaded 0.5 mounting holes, which enable heat sinks or cold plates to attach to the module ...
Page 15
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Thermal Considerations Heat Transfer with Heat Sinks LOCAL AMBIENT TEMPERATURE, T Figure 32. Heat Sink Power Derating Curves; Natural Convection; Transverse Orientation 20 1 IN. HEAT SINK 1/2 IN. HEAT SINK 15 1/4 IN ...
Page 16
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Thermal Considerations Heat Transfer with Heat Sinks Example °C case temperature is desired, what is the minimum airflow necessary? Assume the QHW100F1-Q module is operating at V output current maximum ambient air tempera- ture of 40 ° ...
Page 17
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Outline Diagram Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) x.xx mm ± 0.25 mm (x.xxx in. ± 0.010 in.) Top View Side View 4 ...
Page 18
... QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output Recommended Hole Pattern Component-side footprint. Dimensions are in millimeters and (inches). 5.3 (0.21) 7.62 (0.300) 26.16 (1.030) 15.24 (0.600) 10.9 (0.43) 5.3 3.6 (0.21) (0.14) Ordering Information Please contact your Lineage Power Account Manager or Field Application Engineer for pricing and availability. ...
Page 19
... Data Sheet QHW050F1-Q, QHW075F1-Q, and QHW100F1-Q Power Modules; dc-dc Converters Vdc Input, 3.3 Vdc Output April 2008 Ordering Information (continued) Table 6. Device Accessories Accessory 1/4 in. transverse kit (heat sink, thermal pad, and screws) 1/4 in. longitudinal kit (heat sink, thermal pad, and screws) 1/2 in ...
Page 20
... Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any oduct information. ...