JW100F1 Lineage Power, JW100F1 Datasheet - Page 13

no-image

JW100F1

Manufacturer Part Number
JW100F1
Description
CONVERTER DC/DC 3.3V 66W OUT
Manufacturer
Lineage Power
Series
JW100r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW100F1

Output
3.3V
Number Of Outputs
1
Power (watts)
66W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
66W
Operating Temperature
-40°C ~ 100°C
Efficiency
80%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW100F1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW100F1
Manufacturer:
LUCENT
Quantity:
530
Part Number:
JW100F1
Manufacturer:
LUCENT
Quantity:
20 000
Part Number:
JW100F1
Quantity:
55
Part Number:
JW100F1-(66W)
Manufacturer:
LUCENT
Quantity:
20 000
April 2008
Thermal Considerations
Introduction
Note: Top view, pin locations are for reference only.
Figure 26. Case Temperature Measurement
The temperature at this location should not exceed
100 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
modules is 100 °C, you can limit this temperature to a
lower value for extremely high reliability.
For additional information on these modules, refer to
the Thermal Management JC-, JFC-, JW-, and JFW-
Series 50 W to 150 W Board-Mounted Power Modules
Technical Note
(TN97-008EPS).
Heat Transfer Without Heat Sinks
Increasing airflow over the module enhances the heat
transfer via convection. Figure 31 shows the maximum
power that can be dissipated by the module without
exceeding the maximum case temperature versus local
ambient temperature (T
through 4 m/s (800 ft./min.).
Lineage Power
Measurements shown in millimeters and (inches).
7.6 (0.3)
Location
(continued)
V
ON/OFF
CASE
V
I
I
38.0 (1.50)
(+)
(–)
A
) for natural convection
dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 99 W
+ SEN
– SEN
V
V
TRIM
O
O
(–)
(continued)
(+)
MEASURE CASE
TEMPERATURE HERE
8-716 (C).f
Note that the natural convection condition was mea-
sured at 0.05 m/s to 0.1 m/s (10 ft./min. to 20 ft./min.);
however, systems in which these power modules may
be used typically generate natural convection airflow
rates of 0.3 m/s (60 ft./min.) due to other heat dissipat-
ing components in the system. The use of Figure 31 is
shown in the following example.
Example
What is the minimum airflow necessary for a JW100F
operating at V
maximum ambient temperature of 40 °C?
Solution
Given: V
Determine P
Determine airflow (v) (Use Figure 31.):
Figure 27. JW050F Power Dissipation vs.
9
8
7
6
5
4
3
2
I
T
P
v = 1.7 m/s (340 ft./min.)
0
O
A
I
D
= 54 V
= 20 A
= 40 °C
Output Current
= 15.8 W
1
D
I
(Use Figure 29.):
V
= 54 V, an output current of 20 A, and a
I
= 54 V
V
2
I
= 75 V
OUTPUT CURRENT, I
3
4
5
6
V
O
I
(A)
= 36 V
7
8
9
8-1459 (C)
10
13