JW100A Lineage Power, JW100A Datasheet

no-image

JW100A

Manufacturer Part Number
JW100A
Description
CONVERTER DC/DC 5V 100W OUT
Manufacturer
Lineage Power
Series
JW100r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW100A

Output
5V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
100W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW100A
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW100A1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW100A1
Manufacturer:
TYCO
Quantity:
20 000
Part Number:
JW100A1
Quantity:
55
Part Number:
JW100A1-49
Manufacturer:
DIALIGHT
Quantity:
27
Part Number:
JW100A61
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW100A61
Manufacturer:
ERICSSON
Quantity:
452
Data Sheet
April 2008
The JW050A, JW075A, JW100A, and JW150A Power Modules
use advanced, surface-mount technology and deliver high-
quality, efficient, and compact dc-dc conversion.
Applications
n
n
n
n
Options
n
n
Description
The JW050A, JW075A, JW100A, and JW150A Power Modules are dc-dc converters that operate over an input
voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated
from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maxi-
mum power ratings from 50 W to 150 W at a typical full-load efficiency of 84%.
The sealed modules offer a metal baseplate for excellent thermal performance. Threaded-through holes are pro-
vided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature
set includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applica-
Distributed power architectures
Workstations
Computer equipment
Communications equipment
Heat sinks available for extended operation
Choice of remote on/off logic configuration
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 50 W to 150 W
JW050A, JW075A, JW100A, JW150A Power Modules:
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Assn.
‡ This product is intended for integration into end-use equipment.
All the required procedures for CE marking of end-use equip-
ment should be followed. (The CE mark is placed on selected
products.)
Small size: 61.0 mm x 57.9 mm x 12.7 mm
(2.40 in. x 2.28 in. x 0.50 in.)
High power density
High efficiency: 84% typical
Low output noise
Constant frequency
Industry-standard pinout
Metal baseplate
2:1 input voltage range
Overtemperature protection (100 W and 150 W only)
Overcurrent and overvoltage protection
Remote sense
Remote on/off
Adjustable output voltage: 60% to 110% of V
Case ground pin
ISO9001 Certified manufacturing facilities
UL* 1950 Recognized, CSA
Certified, and VDE 0805 (EN60950, IEC950)
Licensed
CE mark meets 73/23/EEC and 93/68/EEC
directives
C22.2 No. 950-95
O, nom

Related parts for JW100A

JW100A Summary of contents

Page 1

... Description The JW050A, JW075A, JW100A, and JW150A Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maxi- mum power ratings from 150 typical full-load efficiency of 84% ...

Page 2

... Parameter Input Voltage: Continuous: JW050A, JW075A JW100A, JW150A Transient (100 ms; JW100A, JW150A only) I/O Isolation Voltage (for 1 minute) Operating Case Temperature (See Thermal Considerations section.) Storage Temperature Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions ...

Page 3

... JW050A I O, cli JW075A I O, cli JW100A I O, cli JW150A I O, cli = 250 mV) All — η °C) JW050A C η JW075A η JW100A η JW150A All — ° max All — All — max All — All — Min Typ Max 4.92 5 ...

Page 4

... V 0 — 1.2 on/off I — — 1.0 on/off V — — 15 on/off I — — 50 on/off — — — — — 0.5 — 60 — 110 V 5.9* — 7.0* O, clamp T — 105 — C Lineage Power Unit pF M¾ Unit hr. g (oz.) Unit µ nom V °C ...

Page 5

... INPUT VOLTAGE, V Figure 2. Typical JW075A Input Characteristics at Room Temperature Lineage Power JW050A, JW075A, JW100A, JW150A Power Modules: 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 (V) I 8-1159 (C) Figure 3. Typical JW100A Input Characteristics (V) I 8-1131 (C) Figure 4. Typical JW150A Input Characteristics INPUT VOLTAGE, V ...

Page 6

... Figure 5. Typical JW050A Output Characteristics at Room Temperature OUTPUT CURRENT, I Figure 6. Typical JW075A Output Characteristics at Room Temperature (A) O 8-1165 (C) Figure 7. Typical JW100A Output Characteristics 1718 0 (A) O 8-1134 (C) Figure 8. Typical JW150A Output Characteristics Data Sheet April 2008 OUTPUT CURRENT Room Temperature OUTPUT CURRENT, I ...

Page 7

... Output Current at Room Temperature OUTPUT CURRENT, I Figure 10. Typical JW075A Converter Efficiency vs. Output Current at Room Temperature Lineage Power JW050A, JW075A, JW100A, JW150A Power Modules (A) O 8-1161 (C) Figure 11. Typical JW100A Converter Efficiency vs (A) O 8-1132 (C) Figure 12. Typical JW150A Converter Efficiency vs OUTPUT CURRENT, I (A) O Output Current at Room Temperature ...

Page 8

... JW050A, JW075A, JW100A, JW150A Power Modules: dc-dc Converters Vdc Input, 5 Vdc Output 150 W Characteristic Curves (continued) TIME µs/div) Figure 13. Typical JW150A Output Ripple Voltage at Room Temperature Input, I Load TIME, t (100 µs/div) Note: Tested with a 10 µF aluminum and a 1.0 µF ceramic capacitor across the load ...

Page 9

... Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or tan- talum capacitor. Scope measurement should be made using a BNC socket. Position the load between 51 mm and in. and 3 in.) from the module. Figure 18. Peak-to-Peak Output Noise Measurement Test Setup Lineage Power JW050A, JW075A, JW100A, JW150A Power Modules: CURRENT PROBE SUPPLY V (+) I CONTACT 33 µ ...

Page 10

... JW050A, JW075A, JW100A, JW150A Power Modules: dc-dc Converters Vdc Input, 5 Vdc Output 150 W Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i ...

Page 11

... RESISTANCE Figure 21. Effective Circuit Configuration for Single-Module Remote-Sense Operation Lineage Power JW050A, JW075A, JW100A, JW150A Power Modules: Output Voltage Set-Point Adjustment (Trim) Output voltage trim allows the user to increase or decrease the output voltage set point of a module. This is accomplished by connecting an external resistor between the TRIM pin and either the SENSE(+) or SENSE(– ...

Page 12

... JW050A, JW075A, JW100A, JW150A Power Modules: dc-dc Converters Vdc Input, 5 Vdc Output 150 W Feature Descriptions (continued) Output Voltage Set-Point Adjustment (Trim) (continued) V (+) V (+) I O ON/OFF SENSE(+) CASE TRIM V (–) SENSE(– (–) O Figure 22. Circuit Configuration to Decrease Output Voltage 1M 100k 10k ...

Page 13

... The use of Figure 27 is shown in the following example. MEASURE CASE TEMPERATURE HERE Example What is the minimum airflow necessary for a JW100A operating at V (+) maximum ambient temperature of 40 °C? Solution Given (– ...

Page 14

... OUTPUT CURRENT, I Figure 28. JW050A Power Dissipation vs. Output Current OUTPUT CURRENT, I Figure 29. JW075A Power Dissipation vs. Output Current 14 14 (continued (continued Figure 30. JW100A Power Dissipation vs (A) O 8-1182 ( Figure 31. JW150A Power Dissipation vs. (A) O 8-1183 (C) Data Sheet April 2008 OUTPUT CURRENT, I (A) O Output Current V ...

Page 15

... IN. HEAT SINK ca 1/2 IN. HEAT SINK 1/4 IN. HEAT SINK NO HEAT SINK ca Use Figure 32 to determine air velocity for the 1/2 inch heat sink. The minimum airflow necessary for the JW100A mod- ule is 1.3 m/s (260 ft./min.). 2.0 2.5 3.0 (400) (500) (600) ...

Page 16

... JW050A, JW075A, JW100A, JW150A Power Modules: dc-dc Converters Vdc Input, 5 Vdc Output 150 W Thermal Considerations Custom Heat Sinks A more detailed model can be used to determine the required thermal resistance of a heat sink to provide necessary cooling. The total module resistance can be separated into a resistance from case-to-sink ( cs) and sink-to-ambient ( sa) shown below (Figure 33) ...

Page 17

... Side label includes Lineage name, product designation, safety agency markings, input/output voltage and current ratings, and bar code. Lineage Power JW050A, JW075A, JW100A, JW150A Power Modules: 57.9 (2.28) MAX 61.0 (2.40) MAX SIDE LABEL* 1.02 (0.040) DIA ...

Page 18

... JW050A, JW075A, JW100A, JW150A Power Modules: dc-dc Converters Vdc Input, 5 Vdc Output 150 W Recommended Hole Pattern Component-side footprint. Dimensions are in millimeters and (inches). 35.56 (1.400) 50.8 25.40 (2.00) (1.000) 5.1 (0.20) Ordering Information Table 4. Device Codes Input Output Voltage Voltage ...

Page 19

... Dimensions are in millimeters and (inches). 1/4 IN. 1/2 IN. 1 IN. 61 (2.4) 1 1/2 IN. 57.9 (2.28) Figure 34. Longitudinal Heat Sink Lineage Power JW050A, JW075A, JW100A, JW150A Power Modules: 61 (2.4) D000-c.cvs Figure 35. Transverse Heat Sink Comcode 407243989 407243997 407244706 407244714 407244722 407244730 ...

Page 20

... Lineage P ower r eserves the right to mak e c hanges to the produc t(s) or information contained her ein without notice. No liability is ass umed ult of their use or applic ation. No rights under any patent accompany the sale of any product information. © 2008 Lineage Power Corpor ation, (Mesquite International Rights Res er ved. April 2008 ...

Related keywords