BXB150-24S3V3FLTJ Emerson Network Power, BXB150-24S3V3FLTJ Datasheet

CONV DC/DC 100W 3.3V 30A NEG SGL

BXB150-24S3V3FLTJ

Manufacturer Part Number
BXB150-24S3V3FLTJ
Description
CONV DC/DC 100W 3.3V 30A NEG SGL
Manufacturer
Emerson Network Power
Series
BXB150r
Type
Isolated with UVLOr
Datasheet

Specifications of BXB150-24S3V3FLTJ

Output
3.3V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 30A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
100W
Operating Temperature
-40°C ~ 100°C
Efficiency
77%
Approvals
CE, CSA, cUL, UL, VDE
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
100W
Output Voltage
3.3V
Output Current
30A
Approval Bodies
CSA, EN, IEC, UL, VDE
Supply Voltage
36V
Output Power
100 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
30 A
Package / Case Size
2.28 in x 2.4 in x 0.5 in
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
BXB150 Series
Single output
Special Features
• Industry standard footprint
• Input voltage to ETS300-132-2
• Adjustable output voltage
• No minimum load required
• Separate case ground pin
• 2:1 input range for battery
• Undervoltage lockout (UVLO)
• UL, VDE and CSA
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
UL1950
CSA C22.2 No. 950
Total Power:
Input Voltage: 18 - 36 Vdc
# of Outputs:
MTBF >1.4 million hours
(Bellcore 332)
powered applications
safety approvals
150 W
36 - 75 Vdc
Single
Electrical Specifications
Output
Voltage adjustability:
Setpoint accuracy:
Line regulation
Load regulation
Minimum load
Overshoot
Undershoot
Ripple and noise
5 Hz - 20 MHz (see note 1)
Temperature coefficient
Transient response (see note 2)
Remote sense
Low line to high line
Full load to min. load
At turn on and turn-off
3.3 V and 5 V
12V and 15 V
Embedded Power for
Business-Critical Continuity
line drop compensation
±2.0% max. deviation
0.5 Vdc transmission
to within ±1.0%
170 μsrecovery
100 mV pk-pk,
75 mV pk-pk,
60% to 110%
±0.01% / ºC
20 mV rms
30 mV rms
±0.10%
±1.0%
±0.5%
None
None
0 %
Rev.05.13.08
bxb150
1 of 4

Related parts for BXB150-24S3V3FLTJ

BXB150-24S3V3FLTJ Summary of contents

Page 1

... BXB150 Series Single output Total Power: 150 W Input Voltage Vdc Vdc # of Outputs: Single Special Features • Industry standard footprint MTBF >1.4 million hours (Bellcore 332) • Input voltage to ETS300-132-2 • Adjustable output voltage • No minimum load required • Separate case ground pin • ...

Page 2

... G rms (approx.) Continuous, automatic recovery Non-latching Non-latching 110 °C baseplate, automataic recovery Embedded Power for Business-Critical Continuity Telecom Specifications Central office ETS300-132-2 interface A Rev.05.13.08 bxb150 ...

Page 3

... Max 0.5 Through ALL DIMENSIONS IN INCHES (mm) Tolerance : x.xx 0.02in. (0.51mm) x.xxx 0.010in. (0.254mm) Embedded Power for Business-Critical Continuity Regulation Model Number Line Load ±0.05% ±0.1% BXB150-24S3V3FLTJ ±0.05% ±0.1% BXB150-48S3V3FLTJ ±0.05% ±0.1% BXB150-48S05FLTJ ±0.05% ±0.1% BXB150-48S12FLTJ ±0.05% ±0.1% BXB150-48S15FLTJ Pin connections ...

Page 4

... Embedded Power for Business-Critical Continuity Rev.05.13.08 Americas bxb150 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 ...