JW100A1 Lineage Power, JW100A1 Datasheet - Page 12

no-image

JW100A1

Manufacturer Part Number
JW100A1
Description
CONVERTER DC/DC 5V 100W OUT
Manufacturer
Lineage Power
Series
JW100r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW100A1

Output
5V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
100W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW100A1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW100A1
Manufacturer:
TYCO
Quantity:
20 000
Part Number:
JW100A1
Quantity:
55
Part Number:
JW100A1-49
Manufacturer:
DIALIGHT
Quantity:
27
JW050A, JW075A, JW100A, JW150A Power Modules:
Feature Descriptions
Output Voltage Set-Point Adjustment
(Trim)
Figure 22. Circuit Configuration to Decrease
Figure 23. Resistor Selection for Decreased
Figure 24. Circuit Configuration to Increase
12
12
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 50 W to 150 W
100k
100
10k
1M
1k
V
ON/OFF
CASE
V
V
ON/OFF
CASE
V
I
I
I
I
0
(+)
(–)
(+)
(–)
(continued)
Output Voltage
Output Voltage
Output Voltage
SENSE(+)
SENSE(+)
SENSE(–)
SENSE(–)
% CHANGE IN OUTPUT VOLTAGE ( %)
10
V
TRIM
V
TRIM
V
V
O
O
O
O
(+)
(+)
(–)
(–)
(continued)
20
R
adj-down
R
adj-up
30
R
R
LOAD
LOAD
8-748 (C).b
8-715 (C).b
8-879 (C)
40
Figure 25. Resistor Selection for Increased Output
Output Overvoltage Protection
The output overvoltage clamp consists of control cir-
cuitry, independent of the primary regulation loop, that
monitors the voltage on the output terminals. The con-
trol loop of the clamp has a higher voltage set point
than the primary loop (see Feature Specifications
table). This provides a redundant voltage control that
reduces the risk of output overvoltage.
Overtemperature Protection
The 100 W and 150 W modules feature an overtemper-
ature protection circuit to safeguard against thermal
damage.
The circuit shuts down the module when the maximum
case temperature is exceeded. The module restarts
automatically after cooling.
100k
10M
10k
1M
0
Voltage
% CHANGE IN OUTPUT VOLTAGE ( %)
2
4
6
Data Sheet
April 2008
8
Lineage Power
8-880 (C).a
10

Related parts for JW100A1