JC050A1 Lineage Power, JC050A1 Datasheet - Page 8

no-image

JC050A1

Manufacturer Part Number
JC050A1
Description
CONVERTER DC/DC 5V 50W OUT
Manufacturer
Lineage Power
Series
JC050r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JC050A1

Output
5V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
5 VDC @ 10A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CSA, UL, VDE
Product
Isolated
Output Power
50 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
28 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
10 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JC050A1
Manufacturer:
LUCENT
Quantity:
134
Part Number:
JC050A1
Quantity:
55
Part Number:
JC050A150W
Quantity:
228
18 Vdc to 36 Vdc Input, 5 Vdc Output; 50 W to 100 W
8 8
Characteristic Curves
Figure 13.Typical Start-Up from Remote On/Off
Test Configurations
Note: Measure input reflected-ripple current with a simulated source
BATTERY
Figure 14. Input Reflected-Ripple Test Setup
inductance (L
tery impedance. Measure current as shown above.
TO OSCILLOSCOPE
JC100A1; I
TEST
C
ESR < 0.1 Ω
@ 20 ˚C, 100 kHz
S
220 µF
) of 12 µH. Capacitor C
12 µH
O
L
= Full Load
TEST
TIME, t (5 ms/div)
ESR < 0.7 Ω
@ 100 kHz
(continued)
33 µF
CURRENT
PROBE
S
offsets possible bat-
V
V
I
I
(+)
(–)
8-1603 (C)
8-203 (C).l
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or tan-
Figure 15. Peak-to-Peak Output Noise
Note: All measurements are taken at the module terminals. When
Figure 16. Output Voltage and Efficiency
SUPPLY
V
V
RESISTANCE
talum capacitor. Scope measurement should be made using a
BNC socket. Position the load between 51 mm and 76 mm
(2 in. and 3 in.) from the module.
socketing, place Kelvin connections at module terminals to
avoid measurement errors due to socket contact resistance.
O
O
CONTACT
(+)
(–)
Measurement Test Setup
Measurement Test Setup
I
η
I
=
COPPER STRIP
1.0 µF
[Vo(+) – Vo(-)]Io
------------------------------------------ -
[Vi(+) – Vi(-)]Ii
V
V
I
I
(+)
(
)
SENSE(+)
SENSE(
10 µF
V
V
O
O
(
(+)
Lineage Power
March 2008
)
)
SCOPE
DISTRIBUTION LOSSES
×
I
O
100
CONTACT AND
RESISTIVE
LOAD
8-513 (C).d
LOAD
8-749 (C)

Related parts for JC050A1