JC050B1 Lineage Power, JC050B1 Datasheet
JC050B1
Specifications of JC050B1
Available stocks
Related parts for JC050B1
JC050B1 Summary of contents
Page 1
Data Sheet March 2008 JC050B, JC075B, JC100B Power Modules: dc-dc Converters; 18 Vdc to 36 Vdc Input, 12 Vdc Output 100 W The JC050B, JC075B, JC100B Power Modules use advanced, surface-mount technology and deliver high-quality, efficient, compact ...
Page 2
... Symbol Min Typ — — I, max I — — I, max I — — I, max — — — — 5 — — 60 March 2008 Max Unit 40 Vdc 50 Vdc 1500 Vdc 100 °C 110 °C Max Unit 36 Vdc 5.0 A 7 — mAp-p — dB Lineage Power ...
Page 3
... O Load Change from I = 50 Peak Deviation Settling Time (V < 10% of peak deviation) O Table 3. Isolation Specifications Parameter Isolation Capacitance Isolation Resistance Lineage Power 18 Vdc to 36 Vdc Input, 12 Vdc Output 100 W (continued) Device Symbol All All V All All All All All ...
Page 4
... O, clamp Tc March 2008 Typ Max Unit 2,600,000 hr. — 100 (3.5) g (oz.) Min Typ Max Unit 0 — 1.2 V — — 1.0 mA — — — — 50 µA — — — 1 — 110 %V O, nom 13.2 — 16.0 V — 105 — °C Lineage Power ...
Page 5
... INPUT VOLTAGE, V Figure 1. Typical JC050B Input Characteristics at Room Temperature 6.0 5.0 4.0 3.0 2.0 1.0 0 INPUT VOLTAGE, V Figure 2. Typical JC075B Input Characteristics at Room Temperature Lineage Power 18 Vdc to 36 Vdc Input, 12 Vdc Output 100 (V) I 8-1238 (C) Figure 3. Typical JC100B Input Characteristics at = Full Load ...
Page 6
... Figure 7. Typical JC050B Converter Efficiency vs. 8-1240 (C). (A) O 8-1241 (C) Figure 8. Typical JC075B Converter Efficiency vs March 2008 0.7 1.4 2.1 2.8 OUTPUT CURRENT, I (A) O Output Current at Room Temperature 0.5 1 1.5 2 2.5 3 3.5 4 OUTPUT CURRENT Output Current at Room Temperature Lineage Power 3.5 4.2 8-1242 (C). 4.5 5 5.5 6 6.5 (A) 8-1243 (C).a ...
Page 7
... Figure 9. Typical JC100B Converter Efficiency vs. Output Current at Room Temperature TIME ms/div) Figure 10.Typical Start-Up from Remote On/Off JCxxxB1 Full Load O Lineage Power 18 Vdc to 36 Vdc Input, 12 Vdc Output 100 W Test Configurations TO OSCILLOSCOPE BATTERY Note: Measure input reflected-ripple current with a simulated source inductance (L battery impedance ...
Page 8
... If not using the remote on/off feature, do one of the fol- lowing March 2008 (-) terminal ( 1.2 V. The max- on/off during a logic low is 1 mA. The switch on/off on/off on/off For negative logic, short ON/OFF pin to V For positive logic, leave ON/OFF pin open. Lineage Power ). The on/off generated μA. (-) I ...
Page 9
... CONTACT AND RESISTANCE DISTRIBUTION LOSSES Figure 15. Effective Circuit Configuration for Single-Module Remote-Sense Operation Lineage Power 18 Vdc to 36 Vdc Input, 12 Vdc Output 100 W Output Voltage Set-Point Adjustment (Trim) Output voltage trim allows the user to increase or decrease the output voltage set point of a module. This ...
Page 10
... Heat is removed by conduc- tion, convection,a nd radiation to the surrounding environment. Proper cooling can be verified by mea- suring the case temperature. Peak temperature (Tc) occurs at the position indicated in Figure 20. March 2008 10M 1M 100k 10k CHANGE IN OUTPUT VOLTAGE (Δ%) Voltage Lineage Power 8 10 8-880a ...
Page 11
... The use of Figure 21 is shown in the following example. Lineage Power 18 Vdc to 36 Vdc Input, 12 Vdc Output 100 W Example (continued) What is the minimum airflow necessary for a JC100B operating at nominal line, an output current of 8.5 A, and a maximum ambient temperature of 40 ° ...
Page 12
... The module used to collect the data in Figure 25 had a thermal-conductive dry pad between the case and the heat sink to minimize contact resistance. The use of Figure 25 is shown in the following example Lineage Power ) divided by the ) ...
Page 13
... Use Figure 25 to determine air velocity for the0.5 inch heat sink. The minimum airflow necessary for the JC100B mod- ule is 1.7 m/s (340 ft./min.). Lineage Power 18 Vdc to 36 Vdc Input, 12 Vdc Output 100 W Custom Heat Sinks (continued) A more detailed model can be used to determine the ...
Page 14
... I 48.26 (1.900) 4.8 48.3 (1.90) (0.19) March 2008 2.06 (0.081) DIA SOLDER-PLATED BRASS, 2 PLACES–(OUTPUT AND +OUTPUT) MOUNTING INSERTS M3 x 0.5 THROUGH, 4 PLACES V (–) O 10.16 (0.400) 17.78 –SEN (0.700) 25.40 (1.000) TRIM 35.56 +SEN (1.400) V (+) O Lineage Power 8-1190 ...
Page 15
... Positive remote on/off logic JC100B JC100B1 March 2008 35.56 (1.400) 25.40 (1.000) 61.0 17.78 (2.40) 10.16 (0.700) MAX (0.400) MOUNTING INSERTS Device Comcode Code JC050B1 107201667 JC075B1 107310005 JC100B1 107201683 JC050B 107361479 JC075B 107477184 JC100B 107309940 Option Suffix — Lineage Power ...
Page 16
... Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any oduct information. ...