DS450DC-3 Emerson Network Power, DS450DC-3 Datasheet - Page 2

no-image

DS450DC-3

Manufacturer Part Number
DS450DC-3
Description
POWER SUP 12V 450W 1U X 2U X 11"
Manufacturer
Emerson Network Power
Type
Isolatedr
Datasheet

Specifications of DS450DC-3

Output
12V
Number Of Outputs
1
Power (watts)
450W
Mounting Type
Surface Mount
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
12 VDC @ 37A
Size / Dimension
12.03" L x 3.07" W x 1.57" H (305.6mm x 78mm x 40mm)
Power (watts) - Rated
450W
Operating Temperature
-10°C ~ 50°C
Efficiency
87%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Environmental Specifications
Logic Control
PS_ON/L:
(Power supply enable)
VIN_GOOD/H (Input OK):
POK/H (Output OK):
TACH_1:
PS_KILL:
Digital Control:
Operating temperature:
Storage temperature:
Altitude, operating:
Electromagnetic
susceptibility / Input transients:
RoHS & lead-free compliant (no tantalum caps.)
Humidity:
Shock and vibration specificatons complies with Astec Std. Specifications, Q3205
MTBF (observed):
Ordering Information
*Over current latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.
*For 5 Vsb, consult marketing.
DS450DC-3-002
DS550DC-3-003
DS450DC-3
DS550DC-3
Output
Voltage Set Point
Nominal Output
12.0 Vdc
12.0 Vdc
12.0 Vdc
12.0 Vdc
3.3 Vsb
3.3 Vsb
3.3 Vsb
3.3 Vsb
The power supply output will be enabled when this signal is pulled low (< 0.8 V).
HIGH = Output V1 OFF
LOW = Output V1 ON
Active High signal asserted when the input voltage rises above the min input
voltage specified.
This signal is internally pulled up through 4.7 K ohms to the 3.3 V housekeeping
voltage.
Active High signal asserted when the output is within regulation. This signal is
internally pulled up through 1.0 K ohms to the 3.3 V housekeeping voltage.
This open collector signal generates two pulses per each fan revolution. This
signal is eternally pulled up to the housekeeping voltage.
This signal will cause the output to shut down when drive high (> 24 V) or left
floating. The PS_KILL will cause the output to latch off and requires recycle of
PS_ON or DC input to reset.
PMBus - I
-10 °C to 50 °C
-40 °C to +70 °C
10,000 ft.
- EN61000-3-2, -3-3
- EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
- EN55024:1998
20 to 90% RH, non-condensing
500K Hrs at 80%, 40 °C
2
C compliant
Tolerance
Set Point
± 0.2%
± 0.2%
± 0.2%
± 0.2%
± 1%
± 1%
± 1%
± 1%
Regulation
+5 / -3%
+5 / -4%
+5 / -3%
+5 / -4%
+5 / -3%
+5 / -4%
+5 / -3%
+5 / -4%
Total
Minimum
Current
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0A
Maximum
Current
37.0 A
37.0 A
45.0 A
45.0 A
3.0 A
3.0 A
3.0 A
3.0 A
Output Ripple
120 mV
120 mV
120 mV
120 mV
60 mV
60 mV
60 mV
60mV
P/P
Embedded Power for
Business-Critical Continuity
4.9 A Avg, 7 A max
4.9 A Avg, 7 A max
4.9 A Avg, 7 A max
4.9 A Avg, 7 A max
48.0A - 54.0A
48.0A - 54.0A
Over Current
39.5 - 44.4%
39.5 - 44.4%
DS450DC/DS550DC
Reverse Air
Reverse Air
Rev. 03.15.11_79
Standard
Standard
Options
2 of 4

Related parts for DS450DC-3