RPP50-2405S Recom Power Inc, RPP50-2405S Datasheet - Page 3

CONV DC/DC 50W SNGL 5V OUT

RPP50-2405S

Manufacturer Part Number
RPP50-2405S
Description
CONV DC/DC 50W SNGL 5V OUT
Manufacturer
Recom Power Inc
Series
Powerline RPP50r
Type
Isolatedr
Datasheets

Specifications of RPP50-2405S

Output
5V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
6-DIP Module
1st Output
5 VDC @ 10A
Size / Dimension
2.00" L x 1.20" W x 0.46" H (50.8mm x 30.5mm x 11.7mm)
Power (watts) - Rated
50W
Operating Temperature
-45°C ~ 74°C
Efficiency
90%
Product
Isolated
Output Power
50 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
10 A
Isolation Voltage
3 KV
Package / Case Size
50.8 mm x 30.5 mm x 11.7 mm
Output Voltage
5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
30020007
945-1304
1. Typical values at nominal input voltage and no load/full load.
2. Typical values at nominal input voltage and full load.
3. Typical values for ribbed case at nominal input voltage and full load in vertical orientation and with Eurocard-sized PCB ground planes to assist in heat
dissipation. For horizontal orientation, reduce the maximum temperatures by 10°C.
4. The ON/OFF pin voltage is referenced to negative input. The pin is pulled high internally.
5. Requires an external 100µF/100V low ESR capacitor to meet EN61000-4-4 and EN61000-4-5
6. Case l: 50% Stress, Temperature at 50°C (Ground Benign).
7. To ensure a good all-round electrical contact, the baseplate is pressed firmly into place within the aluminium housing.The hydraulic press can leave
tooling marks and deformations to both the housing and baseplate. The case is anodised aluminium, so there will be natural variations in the case
colour and the aluminium is not scratch resistant. Any resultant marks, scratches and colour varations are cosmetic only and do not affect the
operation or performance of the converters.
Safety Standards
Thermal Cycling
Vibration
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
MTBF calculated according to BELLCORE TR-NWT-000332
www.recom-international.com
POWERLINE+
DC/DC-Converter
Notes :
Specifications
ON/OFF control is standard with positive logic: e.g. RPP40-2405SW, RPP50-4805S-B.
Add “1” before the suffix for negative logic: e.g. RPP40-2405SW-1, RPP50-4805S-1B.
Positive logic: 0= OFF, 1 = ON. The converter will be ON if the CTRL is left open.
Negative logic: 1 = OFF, 0 = ON. The converter will be OFF if the CTRL is left open.
(5)
External Output Trimming
Refer to Application Notes for
(5)
suggested Resistor Values
(typical at nominal input and 25°C unless otherwise noted)
(6)
REV: 0/2011
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
W
W
10-55Hz, 12G, 30 Min. along X, Y and Z
RPP50-S
Series
certified UL-60950-1, 1st Edition
complies with MIL-STD-810F
1989 x 10
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria A
Perf. Criteria A
W
PP-39
Class B
Class B
3
hours

Related parts for RPP50-2405S