RPP50-4805S Recom Power Inc, RPP50-4805S Datasheet
![CONV DC/DC 50W SNGL 5V OUT](/photos/8/64/86438/rpp30-w_sml.jpg)
RPP50-4805S
Specifications of RPP50-4805S
945-1306
Available stocks
Related parts for RPP50-4805S
RPP50-4805S Summary of contents
Page 1
... RPP50-4805S REV:0/2009 POWERLINE+ DC/DC-Converter 40/50 Watt Single Output (3) UL-60950-1 Pending RPP40/ RPP50 * ICE Technology ICE (Innovation in Converter Excellence) uses state-of-the-art techniques to minimise internal power dissipation and to increase ...
Page 2
... Output Over Voltage Protection (refer to block diagram in Application Notes) Isolation Voltage Isolation Resistance Isolation Capacitance (refer to block diagram in Application Notes) Operating Frequency RPP40 Operating Temperature Range RPP50 Operating Temperature Range Maximum Case Temperature Storage Temperature Range Over Temperature Protection (refer to block diagram in Application Notes) Thermal Impedance (Natural convection ...
Page 3
... The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is standard, no suffix (Ex. RPP50-2405S) Negative logic ON/OFF option has suffix /N (Ex. RPP50-2405S/N) 5. Requires an external 100µF/100V low ESR capacitor to meet EN61000-4-4 and EN61000-4-5 6. Case l: 50% Stress, Temperature at 50°C (Ground Benign). ...
Page 4
... POWERLINE+ DC/DC-Converter Typical Characteristics RPP40-4805SW Package Style and Pinning (mm) External Output Trimming Refer to Application Notes for suggested Resistor Values PP-20 RPP40/50 Series RPP50-4805SW W W REV: 0/2009 Pin Connections Pin # Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout 4 -Vout Com 5 Trim -Vout ...