LE CW E2B-MXNZ-URVU OSRAM Opto Semiconductors Inc, LE CW E2B-MXNZ-URVU Datasheet

LED OSTAR 4CHIP W/LENS WHT 2700K

LE CW E2B-MXNZ-URVU

Manufacturer Part Number
LE CW E2B-MXNZ-URVU
Description
LED OSTAR 4CHIP W/LENS WHT 2700K
Manufacturer
OSRAM Opto Semiconductors Inc
Type
Starboardr
Series
Ostarr

Specifications of LE CW E2B-MXNZ-URVU

Color
White
Luminous Flux @ Current - Test
630 lm
Current - Test
700mA
Current - Max
1A
Driver Circuitry
No
Voltage
14V
Wavelength
2700K
Configuration
Single
With Connector
No
Voltage - Input
14V
Power - Input
18W
Illumination Color
Warm White
Wavelength/color Temperature
2700 K
Luminous Flux
315 Im
Luminous Intensity
90 cd
Viewing Angle
130 deg
Power Rating
12 W
Operating Voltage
14 V
Operating Current
700 mA
Minimum Operating Temperature
- 40 C
Maximum Operating Temperature
+ 100 C
Number Of Leds
4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
475-2633
Q65110A7852
OSRAM OSTAR - Lighting with Optics (silicone)
Lead (Pb) Free Product - RoHS Compliant
LE CW E2B
Nicht für Neuentwicklungen / Not for new designs
Besondere Merkmale
• Gehäusetyp: OSRAM OSTAR - Lighting
• Besonderheit des Bauteils: extrem hohe
• typischer Farbort: x = 0,42, y = 0,40 nach
• typische Farbtemperatur: 2700 K, 3000 K,
• Farbwiedergabeindex: 80
• Abstrahlwinkel: 130°
• Abstrahlende Fläche: 2,1 mm x 2,1 mm
• Montierbarkeit: verschraubbar
• ESD-Festigkeit: ESD-sicher bis 2 kV nach
• Verpackungseinheit: pro Box 60 Stück
Anwendungen
• Strahler für die Allgemeinbeleuchtung
• Mikroskopbeleuchtung
• Verkehrszeichen
• Hochwertige Blitzlichter
2009-08-06
Helligkeit und Leuchtdichte dank
Oberflächenemission und niedrigem R
CIE 1931 (weiß)
3500 K, 4000 K, 4500K
Technologie: ThinGaN
Leuchtdichte: 12 *10
optischer Wirkungsgrad: 44 lm/W bei 350 mA
(3500 K)
Lötpads für Verdrahtung
JESD22-A114-D
6
cd/m² (3500 K)
®
th
1
Features
• package: OSRAM OSTAR - Lighting
• feature of the device: outstanding brightness
• typ. color coordinates: x = 0.42, y = 0.40 acc.
• typ. color temperature: 2700 K, 3000 K,
• color reproduction index: 80
• viewing angle: 130°
• light emitting surface: 2.1 mm x 2.1 mm
• Luminance: 12 *10
• optical efficiency: 44 lm/W at 350 mA
• mounting methods: screw holes
• ESD-withstand voltage: up to 2 kV acc. to
Applications
• General lighting
• microscope illumination
• VMS (variable message signs)
• high end strobe light
and luminance due to pure surface emission
and low R
to CIE 1931 (white)
3500 K, 4000 K, 4500 K
technology: ThinGaN
(3500 K)
solder pads for wire attachment
JESD22-A114-D
method of packing: 60 pcs per tray
th
6
cd/m² (3500 K)
®

Related parts for LE CW E2B-MXNZ-URVU

LE CW E2B-MXNZ-URVU Summary of contents

Page 1

... OSRAM OSTAR - Lighting with Optics (silicone) Lead (Pb) Free Product - RoHS Compliant LE CW E2B Nicht für Neuentwicklungen / Not for new designs Besondere Merkmale • Gehäusetyp: OSRAM OSTAR - Lighting • Besonderheit des Bauteils: extrem hohe Helligkeit und Leuchtdichte dank Oberflächenemission und niedrigem R • ...

Page 2

... Bestellinformation Ordering Information Typ Type LE CW E2B-MXNZ-URVU LE CW E2B-MYNZ-SRTU LE CW E2B-MYPX-QRRU 3500 E2B-MZPY-ORPU LE CW E2B-MZPY-MRNU 4500 K Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 8 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt geliefert E2B-MZPY-ORPU bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen MZ, NX, NY, NZ, PX oder PY enhalten ist. Um die Liefersicherheit zu gewä ...

Page 3

... Symbol Symbol T board board, stg tot Symbol Symbol E2B Werte Einheit Values Unit – 40 … + 100 °C – 40 … + 100 °C 150 °C 180 for short term °C 2 applications* 100 mA 1000 mA 2000 mA not designed for V reverse operation 18 W Werte Einheit ...

Page 4

... V (min (typ (max (max.) R η (typ.) opt η (typ.) opt (typ.) A Chip (typ E2B Werte Einheit Values Unit 0.42 – 0.40 – 2500 K 4800 K 130 Grad deg. 11.6 V 14.0 V 16.4 V not designed for μ reverse operation A 34 lm/W 44 lm/W 2 ...

Page 5

... Gruppe Cx Group UU 0.456 0.461 0.474 0.469 UT 0.447 0.456 0.469 0.459 US 0.437 0.447 0.459 0.448 UR 0.433 0.437 0.448 0.443 LE CW E2B 2700 OHA03749 Cy 0.426 0.435 0.438 0.429 0.408 0.426 0.429 0.410 0.380 0.408 0.410 0.392 0.380 0.389 0.392 0.383 ...

Page 6

... Gruppe Group 0.409 QU 0.417 0.425 0.417 0.392 QT 0.409 0.417 0.399 0.375 QS 0.392 0.399 0.381 0.367 QR 0.375 0.381 0.373 E2B Cx Cy 0.430 0.417 0.434 0.425 0.447 0.430 0.443 0.421 0.422 0.399 0.430 0.417 0.443 0.421 0.435 0.403 0.415 0.381 0.422 0.399 0.435 ...

Page 7

... Gruppe Group 0.381 MU 0.390 0.397 0.387 0.366 MT 0.381 0.387 0.373 0.352 MS 0.366 0.373 0.358 0.343 MR 0.352 0.358 0.348 E2B Cx Cy 0.374 0.387 0.376 0.397 0.390 0.406 0.387 0.396 0.370 0.373 0.374 0.387 0.387 0.396 0.383 0.380 0.367 0.358 0.370 0.373 0.383 ...

Page 8

... In einer Verpackungseinheit ist immer nur eine Gruppe für jede Selektion enthalten. Note: No packing unit ever contains more than one group for each selection. 2009-08-06 2) Seite 18 Lichtstrom 2) page 18 Luminous Flux Φ (lm) V 180 ... 210 210 ... 240 240 ... 280 280 ... 330 330 ... 390 390 ... 450 450 ... 520 520 ... 610 Wellenlänge Wavelength E2B ...

Page 9

... Seite 18 2) page 18 = 700 mA V λ 500 550 600 2) Seite 18 2) page 19 30˚ 20˚ 10˚ 0˚ 1.0 0.8 0.6 0.4 0.2 0 0.6 0.4 0˚ 9 650 700 750 20˚ 40˚ 60˚ 80˚ 100˚ E2B OHL13674 nm 800 λ OHL03480 120˚ ...

Page 10

... °C F board 0.030 Δ Δ Cx, Cy 0.020 Cy 0.015 Cx 0.010 0.005 0 -0.005 -0.010 0 200 400 600 800 2009-08-06 Relative Lichtfluss Relative Luminous Flux Φ /Φ (700 mA OHL02856 page 18 OHL03725 mA 1200 E2B 2) 6) Seite page °C F board 2 Φ V Φ (700 mA OHL026 ...

Page 11

... Relative Lichtstrom 2) page 19 Relative Luminous Flux Φ OHL03769 60 80 100 ˚C 140 page 18 OHL03677 11 2) Seite 18 2) page 19 Φ (25 ° 700 1.20 Φ V Φ V (25 ˚C) 1.10 1.05 1.00 0.95 0.90 0.85 0.80 0.75 -60 -40 - E2B OHL03771 60 80 100 ˚C 140 T j ...

Page 12

... T Board Zulässige Impulsbelastbarkeit Permissible Pulse Handling Capability = 55 °C Duty cycle D = parameter, T OHL03416 0.005 0.01 0.02 0.05 0.1 0.2 0 100 °C board 2 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0 E2B = OHL03417 0.005 0.01 0.02 0.05 0.1 0.2 0 ...

Page 13

... Seite 18 Maßzeichnung 7) page 19 Package Outlines 2009-08- E2B ...

Page 14

... B B ® LED Product family“. ® LED Product family“. Lötspitze Solder Tip 3.2 mm (Meisel; Chisel) 3.2 mm (Meisel; Chisel) 3.2 mm (Meisel; Chisel E2B can be B Temperatur Lötzeit Temperature Solder Time 250 °C 16 sec. 350 °C 6 sec 250 °C 14 sec. ...

Page 15

... Anpressdruck im Bereich von 0.35MPa; die Verwendung von mind. 3 Schrauben, jeweils um 120° versetzt und eine Schraubensicherung wird empfohlen M3 screws with a maximum torque of 0.8 Nm; typical contact pressure in the range of 0.35 MPa; at lease 3 screws, alignment 120° and screw locking is recommended E2B ...

Page 16

... Method of Packing / Polarity and Orientation Tray label Barcode-Tray-Etikett (BTL) Barcode-Tray-Label (BTL) Data Matrix Code 2009-08-06 7) Seite 18 7) page 19 8.9 (0.350) 210 (8.268) ±1 (0.039) Group: LE xxx xxx xxxx-xxxx-xxxx Bar Code MATERIAL: Batch Material Number 16 Device OHOY2897 DC: Date Code Batch Number OHA02684 LE CW E2B ...

Page 17

... As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. 2009-08-06 Barcode label Länge / length ± 170 5 (6,6929 ±0,19685 E2B Original packing label OHA02886 Höhe / height ± (0,826772 ±0,19685) ...

Page 18

... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 8) page 18 components may only be used in life-support devices or systems OSRAM OS. 2009-08-06 9) page 18 with the express written approval E2B Date of change 2007-10-15 2008-01-10 2008-01-11 2008-02-11 2008-02-25 2009-08-06 ...

Page 19

... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health and the life of the user may be endangered E2B figures. These do not necessarily ...

Related keywords